Riassunto

Introduction

In Algeria, The legal limit of BAC is 0,2g/L. This low rate justifies the use of sensitive and specific techniques to provide accurately results. The objectives are:

1
Compare results of BAC measured by an official method, gas chromatography (HS-CPG/FID) and an automatic method using an enzymatic test Emit®II Plus, designed for the determination of ethanol in serum or plasma, and applicated for analyzing whole blood pretreated.
2
Evoke the problematic of forensic interpretation of the alcohol concentrations perfomed for forensic porposes when the mesured rates are technically validated and correctly reported.

Methods

The procedure adopted to compare the two methods involves a duplicate analyzing of 11 whole blood samples loaded with pure ethanol, by enzymatic method after deproteinization and HS-CPG/FID without any pretreatment. The results are evaluated to estimate differences between the two methods. The postmortem samples of blood are analyzed by these methods in the context of toxicological expertise.

Results

The application of the test Emit®II Plus to whole blood after deproteination made of alcohol measurements by enzymatic method as reliable as those made by HS-CPG/FID with a coefficient of correlation equal 0.999. It is found that for concentrations lower than 0,55g/L, the results of both methods have a high level of similarity. From 0,55g/L, the enzymatic method tends to generate overestimation with an average of 0,13g/L. These overestimations are tolerable insofar as the subject remains under penalty of repression whatever the level of alcohol reached when the measured rate exceeds 0,2g/L. In the situation of analysis for alcohol in postmortem specimens, preanalytical error risks have been detected and complicated the interpretation of the alcohol concentrations.

Conclusion

This enzymatic method is an interesting alternative to the instrumental technique (GC) when the equipment is correctly calibrated and controlled and the results are correctly reported. However, the exclusive and uncritical use for forensic purposes is not recommended. Forensic toxicologists are called on to interpret the alcohol concentrations found in the specimens taking into account the risk of preanalytical errors.

Il testo completo di questo articolo è disponibile in PDF.

© 2014  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 26 - N° 2S

P. S51 - Giugno 2014 Ritorno al numero
Articolo precedente Articolo precedente
  • P51: Respiratory depression induced by a decoction of Papaver somniferum L. in two infants
  • I. Iken, A. Attari, A. Amarti, S. Achour
| Articolo seguente Articolo seguente
  • P53 Automated sample clean-up for a comprehensive forensic toxicology urine screening LC-MS/MS method
  • A. Taylor, M. Jarvis, D. Leach, C. Collins

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.