P53 Automated sample clean-up for a comprehensive forensic toxicology urine screening LC-MS/MS method - 28/06/14

Doi : 10.1016/S2352-0078(14)70114-3 
A. Taylor 1, M. Jarvis 1, D. Leach 2, C. Collins 3
1 AB sciex, concord, Ontario, Canada 
2 Tecan US, inc., Morrisville, North Carolina, United States 
3 Hummingbird research and applications, Newton, Massachusetts, United States 

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 2
Iconografia 0
Video 0
Altro 0

Riassunto

Introduction

(For research use only, not for use in diagnostic procedures). Here we present a novel beta glucuronidase hydrolysis that hydrolyses urine samples in 30 minutes. This in combination with rapid cleanup of samples using disposable pipette extraction (DPX) automated tips using the Tecan Freedom EVO® Liquid Handling Workstation, allows for high throughput analysis.

Methods

Spiked Urine with 157 drugs was hydrolysed with IMCS β-Glucuronidase hydrolysis performed in 30 minutes. All DPXWAX- S automated tip preparations were performed using a Tecan Freedom EVO® Liquid Handling Workstation. The LC-MS/MS system consisted of an Eksigent ekspert™ ultraLC 100 interfaced to an AB SCIEX QTRAP® 4500 LC/MS/MS System. LC separation was performed on a Phenomenex Kinetex 2,6μm C18, 100 Å, 50 × 3mm column at 40°C; 15 minute gradient of water and methanol with ammonium formate buffer; 0.4mL/min flow rate 10μL injection volume.

Results

The data acquisition, processing, and reporting was performed using the Cliquid® software, which enabled the direct import of batch lists from the Freedom Evo® liquid handling system. Upon completion of data acquisition, the software automatically performed quantitation for the 157 analytes included in the method, and automatically generated and printed out reports. The reproducibility of the automated protocol was assessed by preparing and analyzing replicates of each calibration standard, and the measured CVs were less than 15 % over the entire concentration range covered by the assay. The method displayed good linearity for all analytes, with R>0.99. Recoveries for over 60 % of the analytes were greater than 80 %. Not only does method automation eliminate human error, thus increasing reproducibility, it also eliminates subjectivity during data processing, and furthermore has the potential to save a great deal of time.

Conclusion

A rapid urine hydrolysis in 30 minutes followed by automated DPX cleanup using the Tecan Freedom EVO® Liquid Handling Workstation has been investigated and has been shown to provide a viable alternative approach to provide automated sample clean-up for a comprehensive forensic toxicology urine screening LC-MS/MS method.

Il testo completo di questo articolo è disponibile in PDF.

Mappa

Piano inalienabile

© 2014  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 26 - N° 2S

P. S51-S52 - Giugno 2014 Ritorno al numero
Articolo precedente Articolo precedente
  • P52: Forensic alcohol analysis: Analytical requirements and problematics of interpretation
  • A.B. Ndjamaa, N. Abourejal, H. Attallah, H. Rezk-Kallah
| Articolo seguente Articolo seguente
  • P54 Capillary electrophoresis – mass spectrometry for the forensic analysis of cathinone drugs and metabolites
  • A. Taylor, M. Jarvis, J. Hudson

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.