Repérage de la membrane cricothyroïdienne en phase d’apprentissage : valeur ajoutée de l’échographie ? - 09/04/14

Doi : 10.1016/j.annfar.2014.01.006 
N. Barbe a, , P. Martin a, J. Pascal a, C. Heras b, P. Rouffiange c, S. Molliex a
a Service d’anesthésie-réanimation, hôpital Nord, CHU de Saint-Étienne, avenue Albert-Raimond, 42270 Saint-Priest-en-Jarez, France 
b Service de santé publique, hôpital Nord, CHU de Saint-Étienne, avenue Albert-Raimond, 42270 Saint-Priest-en-Jarez, France 
c Service de radiologie centrale, hôpital Nord, CHU de Saint-Étienne, avenue Albert-Raimond, 42270 Saint-Priest-en-Jarez, France 

Auteur correspondant.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 4
Iconografia 2
Video 0
Altro 0

Résumé

Objectifs

La ventilation transtrachéale d’urgence est réalisée après ponction de la membrane cricothyroïdienne (MCT) afin d’assurer l’oxygénation d’un patient non intubable et non ventilable. Le repérage clinique de la MCT est difficile. L’objectif de cette étude est de comparer repérages clinique et échographique de la MCT réalisés par des internes d’anesthésie-réanimation.

Patients et méthodes

Chez 2 volontaires en surpoids, le repérage échographique de la MCT a été réalisé par un médecin référent. Sans rappel anatomique préalable, 12 internes ont défini cliniquement un point de ponction, puis une formation au repérage échographique, un autre point de ponction échoguidé. Pour chaque repérage étaient relevés : pertinence du site de ponction, délai de repérage et difficulté de localisation. Six mois plus tard, les internes ont renouvelé repérages cliniques puis échographiques sur les mêmes volontaires.

Résultats

Lors de l’évaluation initiale, la MCT est correctement localisée par repérage clinique et échographique par respectivement 46 % et 100 % des internes (p<0,05). À six mois, les internes restent plus performants par repérage échographique que repérage clinique (78 % vs 33 %) (p<0,05). Le délai moyen de repérage clinique était chez les 2 volontaires de 15 s [11–18] et 24 s [9–39] (moyenne [IC95 %]) alors qu’il était pour le repérage échographique de 21 s [16–25] et 28 s [19–36] respectivement (NS). Le repérage échographique est considéré comme plus aisé.

Conclusion

L’échographie après une courte phrase d’apprentissage permet d’améliorer le repérage de la MCT par rapport à l’évaluation clinique chez des sujets en surpoids. Ce bénéfice persiste à distance de la formation initiale à ce repérage.

Il testo completo di questo articolo è disponibile in PDF.

Abstract

Objectives

Emergency cricothyroidotomy is recommended as life-saving maneuver when mask ventilation and tracheal intubation are impossible. It requires the puncture of the cricothyroid membrane (CTM) whose clinical identification is difficult. The objective of this study is to evaluate if ultrasound can help locating the CTM by comparing palpation and ultrasonographic evaluation.

Patients and methods

After ultrasound localization of CTM by a referent physician in two overweight volunteers, twelve residents without prior anatomy recall, defined by palpation an entry point for CTM. After a rapid training in CTM ultrasound localization, residents identified an ultrasound-guided puncture point. For each puncture site were registered: relevance, time and ease to localization. Six months later, residents renewed clinical and ultrasound identification of CTM on the same subjects.

Results

The CTM was accurately identified by palpation and ultrasound by 46% and 100% of residents respectively (P<0.05). Six months later, residents remained more effective identifying CTM with ultrasound than with palpation (78% vs. 33%) (P<0.05). Time to localization of CTM by palpation in the 2 volunteers was 15 s [11–18] and 24 s [9–39] (average [CI 95%]) whereas it was 21 s [16–25 s] and 28 s [19–36] by ultrasound respectively (ns). The ultrasound identification of CTM was also considered easier than clinical identification.

Conclusion

Following a limited training phase, ultrasound allowed a more effective localization of CTM by residents when compared to clinical palpation in overweight patients. This benefit remained significant when assessment was repeated 6 months later.

Il testo completo di questo articolo è disponibile in PDF.

Mots clés : Intubation, Ventilation difficile, Ventilation transtrachéale, Membrane cricothyroïdienne, Échographie

Keywords : Difficult tracheal intubation, Difficult mask ventilation, Cricothyroid membrane, Emergency cricothyroidotomy, Ultrasound


Mappa


© 2014  Société française d’anesthésie et de réanimation (Sfar). Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 33 - N° 3

P. 163-166 - Marzo 2014 Ritorno al numero
Articolo precedente Articolo precedente
  • Épidémiologie du risque médico-légal lié à la pratique de la chirurgie ambulatoire en France : données SHAM
  • A. Theissen, F. Fuz, J. Catineau, W. Sultan, M. Beaussier, M. Carles, M. Raucoules-Aimé, P. Niccolai
| Articolo seguente Articolo seguente
  • Phénotypage métabolique par résonance magnétique nucléaire pour l’évaluation périopératoire et en réanimation
  • B.J. Blaise, A. Gouel-Chéron, B. Floccard, G. Monneret, F. Plaisant, D. Chassard, E. Javouhey, O. Claris, B. Allaouchiche

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.