Abbonarsi

Transfusion massive : analyse des pratiques en fonction des dispositifs médicaux disponibles - 26/06/12

Doi : 10.1016/j.annfar.2012.01.031 
C. Bourne a, , D. Cabelguenne a, J.-S. David b, c, C. Rioufol a, V. Piriou b, c
a Service de pharmacie, secteur dispositifs médicaux, centre hospitalier Lyon-Sud, hospices civils de Lyon, 165, chemin du Grand-Revoyet, 69495 Pierre-Bénite cedex, France 
b Département d’anesthésie-réanimation, centre hospitalier Lyon-Sud, hospices civils de Lyon, 165, chemin du Grand-Revoyet, 69495 Pierre-Bénite cedex, France 
c Faculté de médecine Charles-Mérieux, université Lyon-1, 69921 Oullins cedex, France 

Auteur correspondant.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 6
Iconografia 0
Video 0
Altro 0

Résumé

Introduction

Un état des lieux des pratiques et des dispositifs disponibles pour la transfusion en situation d’hémorragie massive a été effectué dans notre unité de déchocage.

Matériel et méthode

Les paramètres influençant le débit ont été identifiés et les techniques d’accélération analysées sur un plan technique et pratique (données fournisseurs et utilisateurs).

Résultats

Le débit est influencé par le gradient de pression et les caractéristiques de l’ensemble du système, de la poche (viscosité des concentrés de globules rouges) à l’abord veineux (cathéters veineux). Trois types de dispositifs d’accélération sont disponibles : les manchons de pression à gonflage manuel associés à un transfuseur par gravité, les transfuseurs à bulbe et les accélérateurs-réchauffeurs (AR). Leurs avantages et inconvénients sont présentés.

Discussion

Les débits maximaux transmis par les fournisseurs ne sont pas les débits réels (absence de prise en compte de la viscosité des CGR et du diamètre du cathéter). Le choix de la méthode d’accélération repose sur les performances techniques : capacité de variation du débit, de réchauffement et purge des bulles d’air, modalités d’utilisation et coût. L’utilisation du transfuseur par gravité équipé d’un manchon de pression doit être limitée aux situations peu graves ou dans l’attente du montage de l’AR (moindre débit, pas de réchauffement des fluides, ni de détection des bulles d’air). Le transfuseur à bulbe n’a pas d’indication dans une unité de déchocage (présence d’un opérateur en permanence pour pomper). Les AR sont indiqués pour tous les types d’hémorragie, ils sont plus sûrs mais imposent un délai de mise en route.

Il testo completo di questo articolo è disponibile in PDF.

Abstract

Introduction

An assessment of practices and available medical devices during the treatment of a massive haemorrhage has been realised in the shock unit of our hospital.

Material and methods

Parameters influencing transfusion flow rate have been identified. Medical devices and equipment to accelerate the flow rate were analyzed on the basis of manufacturers’ data and users opinion in relation with their practices.

Results

The system, from blood bags to venous access, influences flow rate: red blood cell viscosity, catheter and pressure gradient. Three types of acceleration systems are available: accelerated transfusion set, pressure cuff with a gravity blood IV set and fast-flow fluid warmers. Their benefits and disadvantages are presented and discussed.

Discussion

Maximum flow rates noted by manufacturers are not the real values because some parameters such as venous catheter diameter (limitative factor) and the red blood cell viscosity (diluted or not) are not considered. The choice of an infusion system is mainly based on the technical capacities (flow rate fluctuations, pressure gradient on blood bags, warming, air purging), practical modalities of use (medical devices and assembly) and cost. The pressure cuff with transfusion gravity set should be limited to non-critical situations or during the assembly of the fast flow fluid warmers (but no warming fluids, no air embolism prevention). The accelerated transfusion set is not the best option for a shock unit because it needs an operator permanently. The fast-flow fluid warmers are recommended for all types of massive haemorrhages, they are more secure but they require a long time to be assembled.

Il testo completo di questo articolo è disponibile in PDF.

Mots clés : Transfusion massive, Dispositif médical, Débit, Transfuseur, Accélérateur-réchauffeur de fluides, Manchon de pression

Keywords : Massive transfusion, Medical device, Flow rate, IV blood transfusion set, Fast-flow fluid warmer, Pressure cuff


Mappa


© 2012  Société française d’anesthésie et de réanimation (Sfar). Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 31 - N° 6

P. 537-542 - Giugno 2012 Ritorno al numero
Articolo precedente Articolo precedente
  • La période périopératoire de chirurgie carcinologique : un moment crucial ! L’anesthésie locorégionale prévient-elle la récidive des cancers ?
  • H. Beloeil, K. Nouette-Gaulain
| Articolo seguente Articolo seguente
  • Hémodialyse continue avec anticoagulation au citrate chez l’insuffisant hépatique : à propos de trois cas
  • P. Devauchelle, M. Page, P. Brun, C.-E. Ber, J. Crozon, J.-J. Baillon, B. Allaouchiche, T. Rimmelé

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.