Relation between impedance and temperature during radiofrequency ablation of accessory pathways - 12/09/11

Doi : 10.1016/0002-8703(95)90204-X 
S.Adam Strickberger, MD , Srihari Ravi, MD, Emile Daoud, MD, Mark Niebauer, MD, K.Ching Man, DO, Fred Morady, MD
Division of Cardiology, Department of Internal Medicine, University of Michigan Medical Center, Ann Arbor, Mich., USA 

Reprint requests: S. Adam Strickberger, MD, Assistant Professor of Internal Medicine, Division of Cardiology, University of Michigan Medical Center, 1500 East Medical Center Dr., Ann Arbor, MI 48109-0022.

Abstract

Temperature monitoring is a useful tool for radiofrequency ablation of accessory pathways. Impedance monitoring is also helpful, and an impedance fall of 20 ohm may predict coagulum formation. Therefore the purpose of this study was to prospectively quantitate the correlation between impedance and temperature during radiofrequency ablation. Thirty-three consecutive patients underwent radiofrequency ablation with a thermistor ablation catheter with continuous temperature and impedance monitoring during each energy application. The initial and final impedance and temperature measurements for 319 applications of radiofrequency energy were 109 ± 17 ohm and 102 ± 17 ohm (p < 0.0001), respectively, and 37 ± 1° C and 57° ± 11° C (p < 0.0001), respectively. Among the 319 applications of radiofrequency energy, 158 were associated with ≥20° C increase in tissue temperature, and 10 were associated with coagulum formation. A ≥20° C increase in tissue temperature was observed in 84 of 104 applications associated with a 5 to 10 ohm decrease in impedance (81% positive predictive value and 93% negative predictive value). The mean change in impedance for applications associated with and without coagulum formation was −19 ± 7 ohm and −6 ± 6 ohm (p < 0.0001), respectively, and coagulum formation never occurred with less than a 12 ohm decrease. In conclusions successful tissue heating without coagulum formation can be achieved by titrating the power to achieve a 5 to 10 ohm decrement in impedance. Impedance decrements beyond 10 ohm increase the likelihood of coagulum formation.

Il testo completo di questo articolo è disponibile in PDF.

© 1995  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 130 - N° 5

P. 1026-1030 - Novembre 1995 Ritorno al numero
Articolo precedente Articolo precedente
  • Heart rate variability profiles in symptomatic coronary artery disease and preserved left ventricular function: Relation to ventricular tachycardia and transient myocardial ischemia
  • Ad J. van Boven, J.Wouter Jukema, Harry J.G.M. Crijns, Kong I. Lie, on behalf of the Regression Growth Evaluation Statin Study (REGRESS)
| Articolo seguente Articolo seguente
  • Prospective study of retrograde coronary venography in patients with posteroseptal and left-sided accessory atrioventricular pathways
  • Burghard Schumacher, Jürgen Tebbenjohanns, Dietrich Pfeiffer, Heyder Omran, Werner Jung, Berndt Lüderitz

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.