Assessing the severity of mitral stenosis: Variability between noninvasive and invasive measurements in patients with symptomatic mitral valve stenosis - 08/09/11

Doi : 10.1016/S0002-8703(99)70196-1 
Andrew Wang, MD, Thomas Ryan, MD, Katherine B. Kisslo, RDCS, Thomas M. Bashore, MD, J.Kevin Harrison, MD
Division of Cardiology, Department of Medicine, Duke University Medical Center, Durham, NC 27710 

Abstract

Background This study evaluated the correlation and variability between noninvasive and invasive measures of mitral stenosis severity before and after balloon mitral commissurotomy (BMC) in a large group of patients with symptomatic mitral stenosis. Factors related to variability between measurements were determined. Methods The Doppler transmitral gradient, Doppler half-time valve area, and 2-dimensional echocardiographic (2D) mitral valve area (MVA) were measured immediately before and 1 day after BMC in 272 consecutive patients with mitral stenosis and compared with their respective measures during cardiac catheterization. Results The correlation coefficient for the comparison of noninvasive and invasive measurements of the transmitral gradient was 0.63 before BMC and 0.60 after the procedure; for 2D versus Gorlin-derived MVA, 0.39 and 0.57, respectively; and for Doppler half-time versus Gorlin-derived MVA, 0.31 and 0.18, respectively. A large degree of variability in the measurement of MVA was present among the 3 techniques before BMC and increased after BMC. Before BMC, for the comparison of 2D and Gorlin-derived MVA, variables predictive of the discrepancy were age, echocardiographic score, transmitral gradient during catheterization, and cardiac index. For the comparison of Doppler half-time versus Gorlin-derived MVA, age, heart rate during cardiac catheterization and echocardiography, cardiac output and left ventricular end-diastolic pressure predicted the difference between the 2 measures. Conclusions In symptomatic patients with mitral stenosis, there is significant variability between noninvasive and invasive measures of mitral stenosis severity despite careful, reproducible measurements. The difference between noninvasive and invasive measures of MVA before BMC is strongly related to cardiac output. (Am Heart J 1999;138:777-84.)

Il testo completo di questo articolo è disponibile in PDF.

Mappa


 Guest Editor for this manuscript was Blase A. Carabello, MD, Medical University of South Carolina, Charleston, SC.
 Reprint requests: Andrew Wang, MD, Box 3824 Duke University Medical Center, Durham, NC 27710.
 0002-8703/99/$8.00 + 0   4/1/98033


© 1999  Mosby, Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 138 - N° 4

P. 777-784 - Ottobre 1999 Ritorno al numero
Articolo precedente Articolo precedente
  • Costs and cost-effectiveness of routine transesophageal echocardiography in congenital heart surgery
  • Ernest S. Siwik, Michael L. Spector, Chandrakant R. Patel, Kenneth G. Zahka
| Articolo seguente Articolo seguente
  • Corrected TIMI frame count does not predict 30-day adverse outcomes after reperfusion therapy for acute myocardial infarction
  • Deepak L. Bhatt, Stephen G. Ellis, Thomas B. Ivanc, Timothy Crowe, Eva Balazs, Darrell Debowey, Andreas Pangerl, Paul H. Chew

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.