Long-term angiographic results of stenting in chronic total occlusions: Influence of stent design and vessel size - 08/09/11

Doi : 10.1016/S0002-8703(99)70182-1 
Javier Escaned, MD, PhD, Jorge Cortes, MD, Marco A. Alcocer, MD, Javier Goicolea, MD, PhD, Fernando Alfonso, MD, PhD, Antonio Fernandez-Ortiz, MD, PhD, Rosana Hernandez, MD, PhD, Camino Bañuelos, MD, PhD, Carlos Macaya, MD, PhD
Interventional Cardiology Unit, Hospital Clinico San Carlos. Madrid, Spain 

Abstract

Background Although coronary stenting has decreased the high restenosis rate associated with percutaneous transluminal coronary angioplasty of chronic total occlusions (CTOs), the results are still less satisfactory than those found in nonoccluded lesions, at least as reported with the Palmaz-Schatz stent. The present work compares the restenosis rate of other stent designs with that of the Palmaz-Schatz stent. Methods We studied the long-term angiographic outcome of 120 CTOs successfully recanalized with balloon-expandable stents and without concomitant debulking techniques. Angiographic follow-up and full quantitative coronary angiography analysis was prospectively performed in all patients. Three different stent designs were compared: Palmaz-Schatz (n = 47), coil (n = 24), and multicellular (n = 49). Particular attention was paid to their performance in vessels of 3 mm or less and greater than 3 mm in diameter. Restenosis was defined as a 50% or greater diameter stenosis at follow-up. Results Multicellular stents were implanted more frequently in the left anterior descending artery and in patients with multivessel disease. No other significant differences in clinical or angiographic baseline characteristics, including vessel size, were noted between groups. At follow-up, multicellular stents presented a lower restenosis rate (22% vs 36% and 58% in the Palmaz-Schatz and coil stent groups, respectively; P = .01 ) and larger minimal luminal diameters (1.92 ± 0.85 mm vs 1.73 ± 0.98 and 1.38 ± 0.83 mm in the Palmaz-Schatz and coil stent groups, respectively; P = 0.0). The superiority of the multicellular stent design resulted from a lower restenosis rate in vessels of 3.0 mm or less in diameter (20% vs 47% and 79% in the Palmaz-Schatz and coil stent groups, respectively; P = .006). Conclusions These results suggest that the restenosis rate after stent recanalization of CTOs is influenced by both stent design and vessel size and may indicate a superiority of multicellular over Palmaz-Schatz and coil stent designs for this purpose. (Am Heart J 1999;138:675-80.)

Il testo completo di questo articolo è disponibile in PDF.

Mappa


 Reprint requests: Javier Escaned, MD, PhD, Hemodinámica, Hospital Clinico San Carlos, Prof. Martin Lagos S/N, 28040 Madrid, Spain.
 0002-8703/99/$8.00 + 0   4/1/97843


© 1999  Mosby, Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 138 - N° 4

P. 675-680 - Ottobre 1999 Ritorno al numero
Articolo precedente Articolo precedente
  • Systematic primary angioplasty in octogenarian and older patients
  • David Antoniucci, Renato Valenti, Giovanni M. Santoro, Leonardo Bolognese, Guia Moschi, Maurizio Trapani, Enrico Taddeucci, Pier Filippo Fazzini
| Articolo seguente Articolo seguente
  • Histopathology of postpercutaneous transluminal coronary angioplasty remodeling in human coronary arteries
  • Giuseppe Sangiorgi, Allen J. Taylor, Andrew Farb, Andrew J. Carter, William D. Edwards, David R. Holmes, Robert S. Schwartz, Renu Virmani

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.