Abbonarsi

Diagnostic de la carence en fer : évaluation du rapport « récepteur soluble de la transferrine/ferritine » - 01/01/00

M.  Ruivard 1 ,  M.  Boursiac 1 ,  G.  Mareynat 2 ,  A.F.  Sapin 2 ,  L.  Gerbaud 3 ,  H.  Derumeaux 3 ,  A.C.  Fouilhoux 1 ,  P.  Travade 1 ,  P.  Philippe 1

Mostrare le affiliazioni

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 7
Iconografia 2
Video 0
Altro 0

Riassunto

Propos. - Le diagnostic de carence en fer peut être difficile chez des patients hospitalisés : une maladie intercurrente influence directement les paramètres biologiques du statut en fer. Le but de cette étude était donc de déterminer l'efficacité diagnostique de dosages biologiques simples.

Méthodes. - Cette étude prospective sur 8 mois incluait des patients hospitalisés devant subir un prélèvement médullaire. L'absence de fer dans les cellules du système réticuloendothélial de la moelle osseuse définissait la carence en fer. Celle-ci n'était pas retrouvée chez les patients constituant le groupe témoin. L'efficacité diagnostique (sensibilité x spécificité) a été calculée pour chaque paramètre du statut en fer. La valeur seuil retenue était celle donnant la meilleure efficacité diagnostique.

Résultats. - Vingt et un patients (17 femmes, 4 hommes) (âge moyen : 52 ans) présentant une carence en fer ont été inclus dans l'étude. Trente trois patients (20 femmes, 13 hommes) (âge moyen : 60 ans) constituaient le groupe témoin. La meilleure efficacité diagnostique (78 %) a été obtenue par le rapport récepteur soluble de la transferrine/ferritine (sensibilité 81 %, spécificité 97 %). La ferritine, pour une valeur seuil de 60 μg/L, donnait une même spécificité (97 %), avec une moins bonne sensibilité (76 %). L'efficacité diagnostique de la transferrine (> 2,5 g/L) était de 65 % (spécificité de 91 %), alors qu'elle était inférieure à 60 % pour tous les autres paramètres (volume globulaire moyen, coefficient de saturation de la transferrine et fer sérique, récepteur soluble de la transferrine seul, indice de distribution des hématies).

Conclusion. - Chez des patients hospitalisés, le dosage de la ferritine reste l'examen de première intention pour porter le diagnostic de carence en fer, à condition de retenir une valeur seuil élevée (60 μg/L dans cette étude). Du fait de son coût, la détermination du récepteur soluble de la transferrine couplée à la ferritine doit être réservée aux situations difficiles.

Mots clés  : carence en fer ; ferritine ; récepteur soluble de la transferrine ; efficacité diagnostique.

Abstract

Objective. - This study was aimed at determining the diagnostic value of conventional laboratory tests regarding the iron status and serum transferrin receptor in hospitalized patients.

Methods. - Patients who had to undergo bone marrow aspirate examination were included in this 8-month prospective study. Iron deficiency was defined as the absence of stainable iron on bone marrow examination. Patients with stainable iron were included in the control group. The higher value of diagnostic efficacy determined the cut-off value for each parameter of the iron status.

Results. - Twenty-one patients (17 females, four males) (mean age: 52 years) with iron deficiency and 33 control subjects (20 females, 13 males) (mean age: 60 years) were included in the study. The ratio serum transferrin receptor/serum ferritin had the best diagnostic efficiency (78%) with a sensitivity of 81% and a specificity of 97%. Serum ferritin alone with a cut-off value of 60 μg/L had the same specificity (97%) but a lower sensitivity (76%). The diagnostic value of all other analyzed tests was below 66% (transferrin alone, mean corpuscular volume, transferrin saturation, iron, serum transferrin receptor alone, red cell distribution width).

Conclusion. - Among in-patients, ferritin remains the first intention test to diagnose iron deficiency, but the cut-off value should be increased (60 μg/L in this study). The ratio «serum transferrin receptor to serum ferritin» provides the highest specificity with a higher cost and should be used only in doubtful cases.

Mots clés  : iron deficiency ; ferritin ; serum transferrin receptor ; diagnostic efficiency.

Mappa



© 2000  Éditions scientifiques et médicales Elsevier SAS. Tutti i diritti riservati.

Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 21 - N° 10

P. 837-843 - Ottobre 2000 Ritorno al numero
Articolo precedente Articolo precedente
  • Cytokines et anticytokines : un enjeu thérapeutique
  • D. Emilie, P. Galanaud
| Articolo seguente Articolo seguente
  • Particularités des méningites du sujet âgé
  • G. Le Moal, F. Roblot, M. Paccalin, T. Pasdeloup, P. Roblot, B. Becq-Giraudon

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.