Abbonarsi

Prognostic value of absolute versus relative measures of the procedural result after successful coronary stenting: Importance of vessel size in predicting long-term freedom from target vessel revascularization - 03/09/11

Doi : 10.1067/mhj.2001.114199 
Khaled M. Ziada, MD, Samir R. Kapadia, MD, Guido Belli, MD, Penny L. Houghtaling, MS, Anthony C. De Franco, MD, Stephen G. Ellis, MD, Patrick L. Whitlow, MD, Irving Franco, MD, Steven E. Nissen, MD, E.Murat Tuzcu, MD
Department of Cardiology, Cleveland Clinic Foundation. Cleveland, Ohio 

Abstract

Background The procedural result is a major determinant of the incidence of 6-month target vessel revascularization (TVR) after successful coronary stenting. However, the prognostic implications of the different measures of the procedural result or procedural end points have not been directly compared. In this study, we sought to assess and compare the impact of achieving different procedural end points on the long-term (2-year) incidence of TVR. Methods and Results We studied 234 patients in whom 1 or 2 stents were successfully deployed and ultrasound imaging performed after angiographic optimization. End points included a visually estimated angiographic residual stenosis <10% and ultrasound stent-to-mean reference lumen area ≥80%. After 2 years, TVR was required in 48 (20.5%) patients. Qualitative predictors of TVR were vein graft lesions, 3-vessel disease, and baseline TIMI flow grade <3. Quantitatively, reference diameter by quantitative coronary angiography (QCA), final minimum lumen diameter (MLD) by QCA, and in-stent minimum lumen area (MLA) by ultrasound were predictive of TVR. Stent-to-reference ratios were not significantly predictive of TVR. By multivariable analysis, vein graft location and MLA by ultrasound were the only significant predictors of TVR (relative risk, 2.9 [1.5, 5.4] and 0.72 [0.6, 0.9], respectively). Receiver operator curves for MLD by QCA and MLA by ultrasound were similar in predicting TVR. Neither was significantly superior to reference vessel diameter. Conclusions Commonly used angiographic and ultrasound stent-to-reference ratios do not predict the incidence of TVR. Absolute measures of the lumen size (MLA by ultrasound and MLD by QCA) were the most important quantitative predictors of TVR within 2 years. This emphasizes the role of the vessel size as the limiting factor in determining the long-term outcome of coronary stenting. (Am Heart J 2001;141:823-31.)

Il testo completo di questo articolo è disponibile in PDF.

Mappa


 Reprint requests: E. Murat Tuzcu, MD, Cleveland Clinic Foundation, Department of Cardiology-F25, 9500 Euclid Ave, Cleveland, OH 44195. E-mail: tuzcue@ccf.org


© 2001  Mosby, Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 141 - N° 5

P. 823-831 - Maggio 2001 Ritorno al numero
Articolo precedente Articolo precedente
  • Predictive value of presyncope in patients monitored for assessment of syncope
  • Andrew D. Krahn, George J. Klein, Raymond Yee, Allan C. Skanes, for the Reveal Investigators*
| Articolo seguente Articolo seguente
  • Six-month angiographic follow-up after intravascular ultrasound-guided stenting of infarct-related artery: Comparison with non–infarct-related artery
  • Myeong-Ki Hong, Seong-Wook Park, Cheol Whan Lee, Kyoung-Suk Rhee, Jong-Min Song, Duk-Hyun Kang, Jae-Kwan Song, Jae-Joong Kim, Seung-Jung Park

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.