Abbonarsi

Anderson-Hynes dismembered pyeloplasty performed using the da Vinci robotic system - 31/08/11

Doi : 10.1016/S0090-4295(02)01761-2 
Matthew T Gettman a, Richard Neururer a, Georg Bartsch , a, Reinhard Peschel a
a Department of Urology, University of Innsbruck, Innsbruck, Austria 

*Reprint requests: Georg Bartsch, M.D., Department of Urology, University of Innsbruck, Anichstrasse 35, Innsbruck A-6020, Austria

Abstract

Introduction. To evaluate and describe the use of the da Vinci robotic system in performing laparoscopic Anderson-Hynes pyeloplasty.

Technical Considerations. Between June 2001 and February 2002, 9 patients underwent laparoscopic Anderson-Hynes pyeloplasty with the da Vinci telerobotic surgical system. The diagnosis was based on the presenting symptoms and radiologic imaging findings. The technique for da Vinci-assisted Anderson-Hynes pyeloplasty followed the same steps as for conventional laparoscopy. Three transperitoneal laparoscopic ports were required for the robotic system, and a fourth laparoscopic port was used by the assistant for retraction, suction, and introduction of suture. The operative time, suturing time, perioperative complications, and success rates were prospectively evaluated. The mean operative time was 138.8 minutes (range 80 to 215), and the mean suturing time was 62.4 minutes (range 40 to 115). No intraoperative complications or open conversions were required. The estimated blood loss was less than 50 mL in all cases. The mean length of hospitalization was 4.7 days (range 4 to 11). Postoperatively, 1 (11.1%) of 9 patients required open exploration to repair a defect in the renal pelvis. At a mean follow-up of 4.1 months (range less than 1 to 8), all procedures were successful on the basis of the subjective and radiographic data.

Conclusions. All aspects of laparoscopic Anderson-Hynes pyeloplasty were performed using the da Vinci robotic system. da Vinci-assisted procedures resulted in favorable overall operative times, suturing times, perioperative complications, and available success rates, but additional clinical experience is required. Ongoing clinical application of robotic technology in a controlled scientific manner is needed to gauge the effectiveness of this method completely.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2002  Elsevier Science Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 60 - N° 3

P. 509-513 - settembre 2002 Ritorno al numero
Articolo precedente Articolo precedente
  • Simplified management of post-prostate biopsy rectal bleeding
  • Thomas J Maatman, Diane Bigham, Brian Stirling
| Articolo seguente Articolo seguente
  • Use of gelatin matrix to rapidly repair diaphragmatic injury during laparoscopy
  • Sam B Bhayani, Robert L Grubb, Gerald L Andriole

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.