Abbonarsi

SPIRIT IV trial design: A large-scale randomized comparison of everolimus-eluting stents and paclitaxel-eluting stents in patients with coronary artery disease - 12/08/11

Doi : 10.1016/j.ahj.2009.07.025 
Eugenia Nikolsky, MD, PhD a, Alexandra J. Lansky, MD a, Krishnankutty Sudhir, MD, PhD d, Julie Doostzadeh, PhD b, Donald E. Cutlip, MD b, Robert Piana, MD c, Xiaolu Su, MS d, Roseann White, MA d, Charles A. Simonton, MD d, Gregg W. Stone, MD a,
a Columbia University Medical Center and The Cardiovascular Research Foundation, New York, NY 
b Harvard Clinical Research Institute, Boston, MA 
c Vanderbilt University Medical Center, Nashville, TN 
d Abbott Vascular, Santa Clara, CA 

Reprint requests: Gregg W. Stone, MD, Columbia University Medical Center The Cardiovascular Research Foundation 111 E. 59th St., 11th Floor New York, NY 10022.

Riassunto

Background

In the 300-patient SPIRIT II and 1002-patient SPIRIT III randomized trials, the everolimus-eluting stent (EES) compared to the paclitaxel-eluting stent (PES) resulted in reduced angiographic late loss (a primary end point in both trials), noninferior rates of 9-month target vessel failure (a primary end point in SPIRIT III), and reduced rates of target lesion revascularization and major adverse cardiac events (secondary end points). However, neither trial was powered for superiority for clinical end points, and the routine performance of angiographic follow-up may have artificially exaggerated the absolute benefits of EES. The relative efficacy of these 2 stents in patients with diabetes mellitus also remains controversial. We therefore designed a large-scale randomized trial without angiographic follow-up to further assess the differences between these 2 stent platforms.

Study Design

SPIRIT IV is an ongoing prospective, active-controlled, single-blinded, multicenter clinical trial in which 3690 patients with native coronary artery disease have been randomized 2:1 to EES versus PES. Patients with up to 3 de novo native coronary artery lesions (maximum 2 lesions per epicardial vessel) with length ≤28 mm and reference vessel diameter ≥2.5 to ≤4.25 mm were enrolled at 66 US clinical sites. Clinical follow-up at 30, 180, and 270 days; 1 year; and then yearly for up to 5 years is underway. The primary end point is the rate of ischemia-driven target lesion failure at 1 year, a composite measure of safety and efficacy consisting of cardiac death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization, with the trial powered for sequential noninferiority and superiority testing.

Summary

SPIRIT IV is the largest randomized comparison of 2 DES with completed enrollment. The absence of routine angiographic follow-up will allow an accurate assessment of the absolute differences in the clinical safety and efficacy profile between these devices. The magnitude of the study will also permit significant insights to be gained into the relative performance of the 2 stents in important subgroups, including patients with diabetes mellitus.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


 ClinicalTrials.gov number NCT00307047.


© 2009  Mosby, Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 158 - N° 4

P. 520 - Ottobre 2009 Ritorno al numero
Articolo precedente Articolo precedente
  • Design of the DEFINE trial: Determining the EFficacy and Tolerability of CETP INhibition with AnacEtrapib
  • Christopher P. Cannon, Hayes M. Dansky, Michael Davidson, Antonio M. Gotto, Eliot A. Brinton, A. Lawrence Gould, Michael Stepanavage, Sherry Xueyu Liu, Sukrut Shah, Joseph Rubino, Patrice Gibbons, Anne Hermanowski-Vosatka, Bruce Binkowitz, Yale Mitchel, Philip Barter, for the DEFINE investigators 1
| Articolo seguente Articolo seguente
  • Design and rationale of the TRI-stent Adjudication Study (TRIAS) Program
  • Margo Klomp, Marcel A.M. Beijk, Niels J.W. Verouden, Jan G.P. Tijssen, Robbert J. de Winter, on behalf of all TRIAS Investigators a

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.