Abbonarsi

Survival rates as a guide to implanted cardioverter-defibrillator replacement strategies for device recalls—Adding statistical insight to clinical intuition - 09/08/11

Doi : 10.1016/j.ahj.2006.10.029 
Lorne J. Gula, MD, MSc, FRCPC , David Massel, MD, FRCPC, Andrew D. Krahn, MD, FRCPC, FACC, Allan C. Skanes, MD, FRCPC, Raymond Yee, MD, FRCPC, FACC, George J. Klein, MD, FRCPC, FACC
Division of Cardiology, Department of Medicine, University of Western Ontario, London, Ontario, Canada 

Reprint requests: Lorne J. Gula, MD, MSc, FRCPC, London Health Sciences Centre, Arrhythmia Service, 339 Windermere Road, London, Ontario, Canada N6A 5A5.

Riassunto

Background

Recalls and advisories of implanted cardioverter-defibrillators (ICDs) have become an unfortunate reality of cardiac rhythm management. With a paucity of data available on which to base replacement decisions, our goal is to model the potential risks and benefits of ICD generator replacement. The estimated risks are varied through a wide range to determine the potential range of outcomes.

Methods and Results

Using initial estimates of risk derived from real data on 2915 advisory devices from 17 implanting centers, a decision analysis and Markov model were used to estimate survival according to device replacement decision. Survival rates at 5 years with and without device replacement were estimated at 60.38% and 60.66%, respectively. This difference was not significantly different on comparative analysis, using variability determined by Monte Carlo simulation. One-way and two-way sensitivity analyses are presented, demonstrating the minimal effect of varying estimates of risk. Only variation in risk of device failure had a differential effect on survival, with a survival benefit at 7 years if annual risk of device failure is at least 1.8%. Little differential effect on survival was demonstrated by variation of estimates of arrhythmia risk, nonarrhythmic mortality, and postprocedure infection rate.

Conclusions

Survival rates with a generator replacement or nonreplacement strategy in response to ICD recalls are similar and decrease nearly in parallel over time. The main factor with differential effect on survival is risk of device failure, although the level of this risk required to confer a survival advantage to a replacement strategy is quite large.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2007  Mosby, Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 153 - N° 2

P. 253-259 - Febbraio 2007 Ritorno al numero
Articolo precedente Articolo precedente
  • Long-term costs and resource use in elderly participants with congestive heart failure in the Cardiovascular Health Study
  • Lawrence Liao, Kevin J. Anstrom, John S. Gottdiener, Paul A. Pappas, David J. Whellan, Dalane W. Kitzman, Gerard P. Aurigemma, Daniel B. Mark, Kevin A. Schulman, James G. Jollis
| Articolo seguente Articolo seguente
  • Alcohol consumption and risk and prognosis of atrial fibrillation among older adults: The Cardiovascular Health Study
  • Kenneth J. Mukamal, Bruce M. Psaty, Pentti M. Rautaharju, Curt D. Furberg, Lewis H. Kuller, Murray A. Mittleman, John S. Gottdiener, David S. Siscovick

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.