Abbonarsi

Diastolic dysfunction: Improved understanding using emerging imaging techniques - 05/08/11

Doi : 10.1016/j.ahj.2010.06.040 
Daniel Daneshvar, MD, Janet Wei, MD, Kirsten Tolstrup, MD, FACC, Louise E.J. Thomson, MBChB, FRACP, Chrisandra Shufelt, MD, MS, C. Noel Bairey Merz, MD
 Women's Heart Center, Cedars-Sinai Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA 

Reprint requests: C. Noel Bairey Merz, MD, 444 S. San Vicente Blvd, Suite 600, Los Angeles, CA 90048.

Riassunto

Diastolic heart failure is increasing in prevalence. Although the pathophysiology is incompletely understood and current therapeutic strategies are limited, identification of diastolic dysfunction is important. We review the role of contemporary techniques with echocardiography and cardiac magnetic resonance imaging (CMRI) in the assessment of diastolic dysfunction. Cardiac catheterization is the criterion standard for demonstrating impaired relaxation and filling by making direct measurements; however, echocardiography has replaced it as the most clinically used tool. By evaluating mitral inflow pulsed-wave Doppler with and without the Valsalva maneuver, isovolumetric relaxation time, pulmonary venous flow Doppler, color M-mode velocity propagation, tissue Doppler imaging, and speckle tracking, echocardiography is considered an accurate method for diagnosis and grading diastolic dysfunction. Evaluation of diastolic function can also be performed by CMRI. Mitral valve inflow velocities, early deceleration time, and pulmonary vein flow velocities are diastolic parameters that can be measured by phase-contrast CMRI. Cardiac magnetic resonance imaging steady-state gradient echo can evaluate functional dimensions for time-volume curves; and myocardial tagging can assess ventricular diastolic “untwisting,” which may be important for improved pathophysiologic understanding. Studies have compared echocardiography and CMRI for diagnosing diastolic dysfunction in small patient groups with similar results. Cardiac magnetic resonance imaging can now provide clinically relevant data regarding the underlying cause of diastolic dysfunction and offers promise to gain mechanistic insights for therapeutic strategy development and clinical trial planning.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2010  Mosby, Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 160 - N° 3

P. 394-404 - Settembre 2010 Ritorno al numero
Articolo precedente Articolo precedente
  • The efficacy and safety of clopidogrel in vascular surgery patients with immediate postoperative asymptomatic troponin T release for the prevention of late cardiac events: Rationale and design of the Dutch Echocardiographic Cardiac Risk Evaluation Applying Stress Echo-VII (DECREASE-VII) trial
  • Jan-Peter van Kuijk, Michiel T. Voute, Willem-Jan Flu, Olaf Schouten, Michel Chonchol, Sanne E. Hoeks, Eric E. Boersma, Hence J.M. Verhagen, Jeroen J. Bax, Don Poldermans
| Articolo seguente Articolo seguente
  • Influence of transfer-in rates on quality of care and outcomes at receiving hospitals in patients with non–ST-segment elevation myocardial infarction
  • Rajendra H. Mehta, Anita Y. Chen, E. Magnus Ohman, W. Brian Gibler, Eric D. Peterson, Matthew T. Roe, CRUSADE National Quality Improvement Initiative Investigators

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.