Abbonarsi

Retentissements hydroélectrolytiques et acidobasiques de la chimiohyperthermie intrapéritonéale - 13/10/10

Doi : 10.1016/j.annfar.2010.06.021 
J. Raft a, b, , M. Parisot b, F. Marchal c, S. Tala d, E. Desandes d, J.-M. Lalot b, F. Guillemin c, D. Longrois e, C. Meistelman a, b
a Centre Alexis-Vautrin, département d’anesthésie-réanimation, Nancy université, avenue de Bourgogne, 54511 Vandœuvre-lès-Nancy, France 
b Réanimation chirurgicale JM-Picard, CHU Nancy-Brabois, université Henri-Poincaré–Nancy-I, 54511 Vandœuvre-lès-Nancy, France 
c CNRS, centre Alexis Vautrin, département de chirurgie, CRAN, Nancy université, avenue de Bourgogne, 54511 Vandœuvre-lès-Nancy, France 
d Centre Alexis-Vautrin, département de biostastiques, DIM activité médicale, Nancy université, avenue de Bourgogne, 54511 Vandœuvre-lès-Nancy, France 
e Département d’anesthésie-réanimation chirurgicale, hôpital Bichat–Claude-Bernard, Assistance publique–Hôpitaux de Paris, université Paris-VII, France 

Auteur correspondant.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 6
Iconografia 2
Video 0
Altro 0

Résumé

Objectif

La chimiothérapie potentialisée par une hyperthermie intrapéritonéale peropératoire (Chip) est une thérapeutique innovante dans le traitement des carcinoses péritonéales. L’objectif de ce travail a été d’analyser le retentissement de cette procédure sur la fonction rénale, l’équilibre hydroélectrolytique et acidobasique, la fonction respiratoire, l’homéostasie thermique et les lignées sanguines.

Méthode

C’est une étude rétrospective réalisée entre mai 2004 et septembre 2006, sur la prise en charge périopératoire de 20 Chip successives à l’oxaliplatine (n=19) et à la mitomycine C (n=1). Ces Chip ont toutes été réalisées à ventre ouvert avec un bain glucosé à 5 % pour un volume de 2L/m2. Le recueil de l’étude s’est fait jusqu’au septième jour postopératoire.

Résultats

Les principales modifications sont apparues juste après la Chip : augmentation de la diurèse, acidose lactique, hyponatrémie et hyperglycémie (malgré un traitement par insuline). Sur notre série, il n’y a pas eu de retentissement sur la fonction rénale ni sur l’hématopoïèse à sept jours ni sur la gazométrie artérielle.

Conclusion

L’hyperglycémie semblerait expliquer l’augmentation de la diurèse, l’acidose lactique et l’hyponatrémie d’installation très rapide. Ces résultats suggèrent que le contrôle glycémique doit être amélioré afin d’éviter les perturbations métaboliques.

Il testo completo di questo articolo è disponibile in PDF.

Abstract

Background

Hyperthermic intraperitoneal chemoperfusion (HIPEC) is an innovative treatment of the peritoneal carcinomatosis with potential iatrogenicity. This observational study was designed to improve our understanding of HIPEC’s impact on the renal and respiratory functions, on temperature, blood cells counts, body fluids/electrolytes and acid-base balance.

Methods

We retrospectively analyzed the perioperative care of 20 patients that underwent HIPEC with oxaliplatin (n=19) and mitomycin C (n=1). The abdominal cavity was filled with the peritoneal dialysis fluid with dextrose 5%: volume of 2L/m2. Follow-up for the study was stopped on postoperative day 7.

Results

The main changes were appearing just after the HIPEC procedure: increased diuresis, lactic acidosis, hyponatremia and hyperglycaemia (despite aggressive intravenous insulin therapy). In our series, there was no renal failure or impact on blood cells counts until the 7th day, neither some changes on the arterial blood gases.

Conclusion

Hyperglycemia might explain increased diuresis of lactic acidosis and the rapid installation of hyponatremia. Taken together, these results suggest that glycemic control must be improved in order to avoid the other metabolic disturbances.

Il testo completo di questo articolo è disponibile in PDF.

Mots clés : Chimiohyperthermie intrapéritonéale, Oxaliplatine, Gestion périopératoire, Hyperglycémie, Hyponatrémie

Keywords : Hyperthermic intraperitoneal chemoperfusion, Oxaliplatin, Perioperative management, Hyperglycemia, Hyponatremia


Mappa


© 2010  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 29 - N° 10

P. 676-681 - Ottobre 2010 Ritorno al numero
Articolo precedente Articolo precedente
  • Le rFVIIa dans le traitement de l’hémorragie du post-partum : évaluer le rapport bénéfice/risque
  • A.-G. Aya, F.-J. Mercier
| Articolo seguente Articolo seguente
  • Optimisation des prescriptions en réanimation
  • J.-J. Lehot, C. Heuclin, J. Neidecker, R. Cartier, P. Ffrench, M.E. Reverdy, D. Revel, M. Billard, C. Lupo, B. Gonnard, G. Keller, G. Aulagner, O. Bastien

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.