Abbonarsi

Prise en charge des nouveau-nés naissant dans un liquide méconial : évaluation prospective des pratiques - 27/08/10

Doi : 10.1016/j.annfar.2010.05.034 
F. Michel a, , C. Nicaise a, T. Camus b, J.-N. Di-Marco a, L. Thomachot a, R. Vialet a, C. Martin a, P. Lagier a
a Unité de réanimation pédiatrique et néonatale, unité de brûlés pédiatriques, département d’anesthésie-réanimation, centre hospitalo-universitaire Nord, Assistance publique–Hôpitaux de Marseille, faculté de médecine de Marseille, université de la Méditerranée, chemin des Bourrelys, 13915 Marseille cedex 20, France 
b Maternité Catherine-Baret, CHR de Pertuis, Pertuis, France 

Auteur correspondant.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 5
Iconografia 1
Video 0
Altro 0

Résumé

Objectif

Un protocole de prise en charge des enfants naissant dans un liquide amniotique méconial (LAM), basé sur la réalisation d’une aspiration trachéale immédiate (ATI) en fonction de l’adaptation néonatale a été établi en 2003 au sein du réseau de périnatalité. Cette étude a évalué l’application de ce protocole trois ans après sa mise en place.

Type d’étude

Cohorte prospective.

Patients et méthodes

Nous avons mené un court questionnaire sur les pratiques de l’ATI au sein du réseau, puis une évaluation de la prise en charge et de l’évolution immédiate de tous les nouveau-nés à terme présentant un LAM particulaire a été réalisée par questionnaire.

Résultats

Parmi 6761 naissances, 199 (3 %) présentaient un LAM. Cinquante-deux nouveau-nés (26 %) étaient non vigoureux ; 22 d’entre eux (42 %) ont eu une ATI. Cent quarante-sept enfants (74 %) étaient vigoureux. Une ATI a été réalisée chez 27 (18 %) d’entre eux. Pour les enfants non vigoureux, le protocole était mieux suivi en maternité de niveau III. Pour les enfants vigoureux, le protocole était moins bien suivi en maternité de niveau IIA. Parmi les 52 enfants non vigoureux, huit (15 %) ont présenté un syndrome d’inhalation méconiale (SIM) dont cinq qui avaient eu une ATI. Un seul SIM est survenu parmi les enfants vigoureux mais une infection ne pouvait être exclue.

Conclusion

Les recommandations concernant l’ATI ont été suivies dans 70 % des cas et pour 42 % des enfants étant nés non vigoureux. Nous devons améliorer la formation et la diffusion des nouveaux protocoles.

Il testo completo di questo articolo è disponibile in PDF.

Abstract

Objective

Regional guideline for immediate tracheal suctioning (ITS) in vigorous and non-vigorous infants born through meconium-stained amniotic fluid (MSAF) has been established in 2003. The objective of this study was to evaluate guideline application.

Study design

Prospective cohort.

Patients and methods

The first part of the study was a short survey about ITS practices in maternity hospitals then, management and early evolution of babies born through particulate MSAF was evaluated by questionnaire.

Results

Among 6761 neonates, 199 (3%) were born with MSAF. Early clinical evaluation showed 52 (26%) non-vigorous neonates; 22 of them (42%) have had an ITS. One hundred and forty-seven neonates were vigorous (74%); 27 of them (18%) have had an ITS. Implementation of recommendations in non-vigorous babies was better in maternities of level III, while they were lower in maternities of level IIA for vigorous babies. Among 52 non-vigorous children, eight had a meconium aspiration syndrome (MAS), including five who had an ITS. One MAS occurred in vigorous babies but infection could not be excluded.

Conclusion

Recommendations for ITS were implemented in 70% of cases but only in 42% of cases in non-vigorous babies. We have to improve formation and circulation of new recommendations.

Il testo completo di questo articolo è disponibile in PDF.

Mots clés : Liquide amniotique méconial, Syndrome d’inhalation méconiale, Nouveau-né, Détresse respiratoire, Aspiration trachéale, Intubation, Réanimation, Protocoles

Keywords : Meconium-stained fluid, Meconium aspiration syndrome, Newborn, Tracheal suction, Intubation, Resuscitation, Guidelines


Mappa


© 2010  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 29 - N° 9

P. 605-609 - Settembre 2010 Ritorno al numero
Articolo precedente Articolo precedente
  • Editorial Board
| Articolo seguente Articolo seguente
  • Analgésie péridurale continue versus bloc continu du compartiment psoas pour l’analgésie postopératoire après chirurgie majeure du bassin ou du fémur chez l’enfant : étude prospective comparative randomisée
  • C. Dadure, S. Bringuier, O. Mathieu, O. Raux, A. Rochette, N. Canaud, W. Javitary, X. Capdevila

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.