Abbonarsi

Une échancrure intercondylienne antéro-supérieure étroite augmenterait le risque de syndrome du cyclope après une reconstruction du LCA par une technique d’autogreffe courte DT4 - 24/08/24

A tight anterosuperior intercondylar notch may increase the risk of cyclops syndrome after anterior cruciate ligament reconstruction using a quadruple semi-tendinosus short autograft

Doi : 10.1016/j.rcot.2024.06.004 
Grégoire Rougereau 1, , Marie Eva Rollet 1, Hugues Pascal-Moussellard 1, Benjamin Granger 2, 3, Frédéric Khiami 1, 4
1 AP–HP, université de la Sorbonne, hôpital de la Pitié-Salpêtrière, département de chirurgie orthopédique et traumatologique, 47-83, boulevard de l’Hôpital, 75013 Paris, France 
2 AP–HP, université de la Sorbonne, hôpital de la Pitié-Salpêtrière, département de santé publique, d’épidémiologie et de biostatistiques, 47-83, boulevard de l’Hôpital, 75013 Paris, France 
3 Pierre-Louis institut d’épidémiologie et de santé publique, IPLESP, PEPITES, équipe, Inserm U1136, Paris, France 
4 Groupe chirurgie du sport, clinique du sport, boulevard Saint-Marcel, Paris, France 

Grégoire Rougereau, hôpital Mignot, service de chirurgie orthopédique et traumatologique, Le Chesnay, France.hôpital Mignot, service de chirurgie orthopédique et traumatologiqueLe ChesnayFrance

Résumé

Objectif

Le syndrome du cyclope est défini par un flessum irréductible du genou dû à la formation d’un nodule fibreux à la partie antérieure de l’échancrure intercondylienne. Les facteurs de risque identifiés sont nombreux (raideur préopératoire, malposition du tunnel tibial, contracture des ischio-jambiers…). L’objectif principal était de déterminer si la taille de l’échancrure intercondylienne avait un impact sur le risque de survenue d’une rupture de greffe ou d’un syndrome du cyclope après reconstruction du ligament croisé antérieur (LCA) par une technique DT4. L’objectif secondaire était de déterminer si la taille de l’échancrure avait un impact sur le résultat fonctionnel.

Hypothèse

L’hypothèse était qu’une échancrure étroite constituait un facteur de risque de syndrome de cyclope et de mauvais résultats.

Méthodes

Tous les patients opérés consécutivement d’une reconstruction du LCA par DT4 ont été inclus rétrospectivement. Cent vingt patients ont été analysés après un suivi moyen de 2,4±0,8 ans. Toutes les mesures IRM préopératoires ont été effectuées par un seul opérateur sénior, en utilisant l’indice de largeur de l’encoche (notch width index, NWI) et l’indice FK.

Résultats

Sept patients (120 ; 5,8 %) avaient présenté une rupture de leur greffe et 20/120 (16,7 %) un syndrome de cyclope. Au dernier suivi, 26/120 patients (21,7 %) n’avaient pas repris d’activité sportive et seulement 47/120 (39,2 %) avaient repris le même sport au même niveau qu’avant l’accident initial. Le score de Lysholm était de 87,9±13,5 et l’IKDC subjectif de 84±13. Une échancrure étroite était associée à un moins bon taux de retour au sport (p=0,001), de retour au même sport (p<0,0001) et du niveau sportif par rapport à avant l’accident initial (p=0,004). En analyse multivariée, seule une diminution de l’indice FK était associée au risque de syndrome du cyclope (p<0,0001). Un indice FK inférieur à 0,18 avait une sensibilité de 85 % et une spécificité de 78 % pour prédire la survenue d’un cyclope.

Conclusion

Une échancrure intercondylienne antéro-supérieure étroite pourrait augmenter le risque de syndrome du cyclope après une reconstruction du LCA utilisant une technique d’autogreffe DT4, mais n’influençait pas le risque de rupture du greffon.

Niveau de preuve

IV ; étude de cohorte observationnelle rétrospective.

Il testo completo di questo articolo è disponibile in PDF.

Summary

Background

Cyclops syndrome is loss of terminal knee extension caused by a fibrous nodule developed in the anterior intercondylar notch. The many known risk factors include preoperative motion-range limitation, tibial tunnel malposition, and tight hamstrings. The primary objective of this study was to assess whether intercondylar notch size was associated with the risk of cyclops syndrome or graft tear after anterior cruciate ligament (ACL) reconstruction using a quadruple semi-tendinosis autograft. The secondary objective was to determine whether intercondylar notch size was associated with functional outcomes.

Hypothesis

A narrow intercondylar notch is associated with higher risks of cyclops syndrome and poor functional outcomes.

Methods

Consecutive patients who underwent ACL reconstruction by quadruple semi-tendinosus autograft were included retrospectively. Preoperative magnetic resonance imaging scans were assessed by a single senior surgeon who determined the conventional notch width index (NWI) and the anterior NWI (aNWI) for each patient.

Results

The 120 included patients had a mean follow-up of 2.4±0.8 years. Among them, 20 (16.7%) experienced cyclops syndrome and 7 (5.8%) graft rupture. At last follow-up, 26 (21.7%) had not returned to sports and only 47 (39.2%) had returned to sports at the pre-injury level. The mean Lysholm score was 87.9±13.5 and the main subjective IKDC score was 84±13. A narrow notch was significantly associated with lower likelihoods of returning to sports (p=0.001), returning to the same sport (p<0.0001, and returning to the pre-injury sport level [p=0.004]). By multivariate analysis, only the aNWI index was significantly associated with the risk of cyclops syndrome (p<0.0001). An aNWI index lower than 0.18 had 85% sensitivity and 78% specificity for predicting cyclops syndrome.

Conclusion

A narrow anterosuperior intercondylar notch may increase the risk of cyclops syndrome after ACL reconstruction using a quadruple semi-tendinosus graft but is not associated with the risk of graft rupture.

Level of evidence

IV; retrospective observational cohort study.

Il testo completo di questo articolo è disponibile in PDF.

Mots clés : Encoche intercondylienne, Rupture du ligament croisé antérieur, Syndrome de cyclope, Flessum, Complication

Keywords : Intercondylar notch, Anterior cruciate ligament tear, Cyclops syndrome, Knee extension deficit, Complication


Mappa


 Ne pas utiliser, pour citation, la référence française de cet article, mais celle de l’article original paru dans Orthopaedics & Traumatology: Surgery & Research, en utilisant le DOI ci-dessus.


© 2024  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 110 - N° 5

P. 707-715 - Settembre 2024 Ritorno al numero
Articolo precedente Articolo precedente
  • Résultats fonctionnels et centrage de la cupule dans les prothèses totales de hanche après fracture de l’acétabulum, à propos de 367 cas
  • Jérôme Tonetti, Guillaume Riouallon, Pierre Martz, Régis Bernard de Dompsure, Roger Erivan, Arthur Guignard, Joris Tiercelin, Arthur Schmitz, Baptiste Belvisi, Pierre-Emmanuel Moreau, Kim Binheng, Asma Bengana, Mehdi Boudissa, Nicolas Reina
| Articolo seguente Articolo seguente
  • L’utilisation de plaque verrouillée dédiée réduit le risque de pseudarthodèse dans l’arthrodèse talo-crurale à ciel ouvert chez les patients obèses
  • Claire Nicot, Guillaume David, Clément Marc, Laurent Hubert, Louis Rony

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.