Validation of diffusion tensor imaging for diagnosis of traumatic brain injury - 09/04/24

Doi : 10.1016/j.neuri.2024.100161 
Micah Daniel Vinet a, b, , 1 , Alexander Samir Ayoub a, c, 2 , Russell Chow d , Joseph C. Wu e, 3
a Henry Samueli School of Engineering, University of California, Irvine, CA 92697-4550, United States 
b Henry Samueli School of Bioengineering University of California, Los Angeles, CA, 90095, United States 
c Creighton University, School of Medicine, Phoenix Health Sciences Campus, Phoenix, AZ 85012, United States 
d Johns Hopkins School of Engineering, United States 
e Department of Psychiatry and Human Behavior, University of California, Irvine, CA 92697-4550, United States 

Corresponding author at: Henry Samueli School of Engineering, University of California, Irvine, CA 92697-4550, United States.Henry Samueli School of EngineeringUniversity of CaliforniaIrvineCA92697-4550United States

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Background and Purpose

With an increased need for standardized methodology in accurate diagnosis of Traumatic Brain Injury (TBI), Diffusion Tensor Imaging (DTI) has provided promising diagnostic results as an adjunct modality yet remains underutilized. The purpose of this study was to validate the use of DTI with Statistical Parametric Mapping (SPM) for Traumatic Brain Injury (TBI) supporting its use as a diagnostic tool.

Materials and Methods

This study was retrospective and compared controls to patients clinically diagnosed with TBI. Forty-two controls (mean age = 34.1; range, 19 - 58; 28 Males and 13 Females) were screened (n = 41) for cognitive impairment and neurological abnormality. Two cohorts, each of eighteen patients (first cohort: mean age, 41.8; range, 23 - 70; 9 Males and 9 Females; second cohort: mean age, 45.7; range, 23 - 68; 9 Males and 9 Females) clinically diagnosed with TBI (n = 36) were pooled. DTI image acquisition was obtained using a 3 Tesla MRI scanner. DTI images were analyzed through voxel-based t-tests using SPM comparing each individual to the normative control group to generate z-maps for each individual control and each individual patient with a TBI. Test statistics were ranged for p-values (0.001-0.05) and cluster extent values (0, 30, 60, 65, 70, 75). Area Underneath A Receiver Operating Characteristic Curve (AUCROC) was used to validate diagnostic capability. AUCROC analysis was conducted on all sets of p-value and extent threshold values. Significance of results was determined by examining the AUCROC values.

Results and Conclusions

A maximal AUCROC of 1.000 was obtained across the p-value range and cluster extent thresholding values specified across the two cohorts. The high AUCROC supports validation of the methodology presented and the use of diffusion tensor imaging and SPM as an adjunct diagnostic tool for TBI.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Traumatic brain injury, Diffusion tensor imaging, Area under the operating characteristic curve, Statistical parametric mapping, Image segmentation, Neuroradiology


Mappa


© 2024  The Authors. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 4 - N° 2

Articolo 100161- Giugno 2024 Ritorno al numero
Articolo precedente Articolo precedente
  • Transarterial AVM embolization using Tsinghua grading system: Patient selection and complete obliteration
  • Huachen Zhang, Youle Su, Shikai Liang, Xianli Lv
| Articolo seguente Articolo seguente
  • Brain tumor segmentation with advanced nnU-Net: Pediatrics and adults tumors
  • Mona Kharaji, Hossein Abbasi, Yasin Orouskhani, Mostafa Shomalzadeh, Foad Kazemi, Maysam Orouskhani

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.