Réduction du temps opératoire et des gains fonctionnels en utilisant une planification préopératoire par modèle 3D obtenu par une imprimante personnelle pour les révisions acétabulaires de prothèse totale de hanche avec perte de substance acétabulaire Paprosky IIA-IIIB - 27/09/22

Improvement of surgical time and functional results after Do-It-Yourself 3D-printed model preoperative planning in acetabular defects Paprosky IIA-IIIB

Doi : 10.1016/j.rcot.2022.03.011 
Alex Dos Santos-Vaquinhas a, Irene Isabel López-Torres a, José Antonio Matas-Diez a, José Antonio Calvo-Haro a, b, Javier Vaquero a, b, Pablo Sanz-Ruiz a, b,
a Department of Orthopaedic Surgery, Hospital General Universitario Gregorio Marañón, C/Doctor Esquerdo 46, 28007 Madrid, Spain 
b Faculty of Medicine, Universidad Complutense de Madrid, Av. Séneca 2, 28040 Madrid, Spain 

Corresponding author. San Martin de Porres no 22, 5o D, 28035 Madrid, Spain.San Martin de Porres no 225o DMadrid28035Spain

Abstract

Introduction

The correct positioning of the implant in revision total hip arthroplasty (rTHA) is critical to obtaining substantial functional outcomes, and to avoiding complications. Current literature supports three dimensional (3D)-printed models as potentially useful tools for preplanning, as well as the “do it yourself (DIY)” methodology to reduce both the time and costs of this procedure. However, no study has determined the efficacy of both methods combined in a cohort of patients with severe acetabular defects. In the lack of bibliography, we performed rTHA after preoperative planning by DIY-3D printed models to evaluate its influence in: 1) the surgical time, 2) the functional scores, 3) the intra and postoperative complications, and 4) the reconstruction of the center of rotation (COR) of the hip.

Hypothesis

Preoperative planning through 3D-DIY printed models will both improve the accuracy of the implant positioning, and the surgical time, leading the latter to improved functional scores and reduced complications.

Materials & methods

A comparative study of 21 patients with Paprosky IIB to IIIB acetabular defects who underwent rTHA after 3D-printed model preoperative planning by the DIY method between 2016 and 2019 was conducted. A historical cohort of 24 patients served as the comparator. Surgical time, reconstruction of the COR, functional scores, and complications were analyzed.

Results

The mean follow-up was 32.4 (range, 12 to 60) months. All the patients showed significant improvement of the Harris hip score (HHS) after the operation (3D group: 26.58±10.73; control group 22.47±15.43 (p=0.00)). In the 3D-printed model preoperative planning group the mean operation time and the intraoperative complications were significantly lower (156.15±43.03min vs 187.5±54.38min (p=0.045); and 19% vs 62.5% (p=0.003), respectively), and the HHS and patient satisfaction score (PSS) were significantly greater (83.74±8.49 vs 75.59±11.46 (p=0.019); and 8.17±0.88 vs 7.36±1.17 (p=0.023), respectively). No differences were found in the postoperative complications, nor in the restoration of the COR as determined from the acetabular index, verticalization or horizontalization, although the acetabular index was closer to the intended one in the 3D-printed model planning group (46.67°±7.63 vs 49.22±8.1 (p=0.284)).

Conclusion

Preoperative planning of severe acetabular defects through 3D-printed models shortens the surgical time, leading to a decrease in complications and thus to better functional outcomes and greater patient satisfaction. Moreover, the DIY philosophy could decrease both the time and costs of traditional 3D planning.

Level of evidence

III, retrospective case matched study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Acetabular defect, Joint revision, 3D printing, DIY philosophy



 Cet article peut être consulté in extenso dans la version anglaise de la revue Orthopaedics & Traumatology: Surgery & Research sur Science Direct (sciencedirect.com) en utilisant le DOI ci-dessus.


© 2022  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 108 - N° 6

P. 741-742 - Ottobre 2022 Ritorno al numero
Articolo precedente Articolo precedente
  • La modularité métaphysaire dans les tiges fémorales de reprise a-t-elle sa place pour des pertes osseuses inférieures à IIIb ? Résultats cliniques et radiologiques d’une série de 163 tiges modulaires fémorales
  • Marion Soleilhavoup, Guillaume Villatte, Sébastien Cambier, Stéphane Descamps, Stéphane Boisgard, Roger Erivan
| Articolo seguente Articolo seguente
  • Comparaison des résultats fonctionnels de la prise en charge des fractures péri-prothétiques de hanche avec descellement de l’implant fémoral ostéosynthèse par plaque verrouillée avec ou sans reprise de l’implant fémoral
  • Tristan Vialla, Dong Tran-Minha, Florian Barbottea, Alexandre Heraulta, Matthieu Ehlinger, Xavier Ohla, Henri Favreaub, Renaud Sibonia

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.