Évaluation expérimentale des déplacements des fragments osseux avec un fixateur hexapode au moyen de diodes infrarouge sur os synthétique - 23/08/22

Experimental assessment of changes in bone fragment position using infra read diodes on saw bone models with a hexapod fixator

Doi : 10.1016/j.rcot.2022.03.003 
Piotr Morasiewicz a, b, , Bartosz Martyniuk c, Andżelika Pajchert Kozłowska a, Jarosław Filipiak c
a Wrocław Medical University, Department and Clinic of Orthopaedic and Traumatologic Surgery, Borowska 213, 50-556 Wrocław, Poland 
b Institute of Medical Sciences, University of Opole, Department of Orthopaedic and Traumatologic Surgery, al. Witosa 26, 45-401 Opole, Poland 
c Wrocław University of Science and Technology, Department of Biomedical Engineering, Mechatronics and Theory of Mechanisms, Łukasiewicza 7/9, 50-371 Wrocław, Poland 

Auteur correspondant.

Abstract

Background

The purpose of this study was an experimental assessment of changes in bone fragment position in patients with nonunion of the tibia treated with a hexapod fixator.

Hypothesis

We hypothesized that the use of hexapod fixators leads to differences between the planned and actual position of bone fragments.

Methods

The study was conducted in physical models of the hexapod fixator–bone fragment system. Bone fragment displacement was measured using the Optotrak Certus Motion Capture System. We assessed differences between the planned and actual position of bone fragments.

Results

Assessment of bone fragment compression demonstrated a difference between the target and actual correction ranging from 1.5% to 13.2% (depending on the force applied to bone fragments) for configuration 1, from 17% to 21.3%for configuration 2,and from 13.2%to17.9% for configuration 3. The achieved varus deformity correction constituted 93.7–98.4%of the target correction for configuration 2 and 98.3–98.9%of the target correction for configuration 3.Torsional deformity correction showed considerable discrepancies between the target and achieved correction, ranging from 65.6% to 83%.

Discussion

The value of the applied compression force had no marked effect on the differences between the target and achieved correction or on the magnitude of unintended rotational and transverse displacement of bone fragments. The use of hexapod fixators helped achieve complete correction of the simulated varus deformity; however, complete correction of torsional deformities was not achieved. Deformity correction in physical models with the use of a hexapod fixator yielded instances of unintended rotational and transverse bone-fragment displacement. The use of hexapod fixators in physical models leads to differences between the planned and actual position of bone fragments.

Level of Evidence

IV, case series.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Experimental, Bone fragment position, Tibial nonunion, Hexapod fixator



 Cet article peut être consulté in extenso dans la version anglaise de la revue Orthopaedics & Traumatology: Surgery & Research sur Science Direct (sciencedirect.com) en utilisant le DOI ci-dessus.


© 2022  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 108 - N° 5

P. 553 - Settembre 2022 Ritorno al numero
Articolo precedente Articolo precedente
  • Fractures de la diaphyse humérale : résultats de l’enclouage antérograde percutané par clou Telegraph® long avec verrouillage distal dynamique
  • Amine El Ghazoui, Jamal Haddaoui, El Mostafa Zahar, Noureddine Sekkach
| Articolo seguente Articolo seguente
  • Quel est le meilleur fixateur externe pour la fixation des fractures de la diaphyse tibiale par arme à feu ?
  • Alkan Bayrak, Ömer Polat, Hüseyin Tamer Ursavaş, Kadir Gözügül, Vedat Öztürk, Altuğ Duramaz

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.