Abbonarsi

What do we know about the positional isomers of 2C-B? Study through real hair cases: The role of high-resolution mass spectrometry (HRMS) - 15/08/22

Doi : 10.1016/j.toxac.2022.06.316 
J.M. Matey 1, , G. Montalvo 2, C. García-Ruíz 2, F. Zapata 3, A. Pedregosa 1, C. García-Caballero 1, V. González del Campo 1, M.A. Martínez 1
1 Drug Department. National Institute of Toxicology and Forensic Sciences. Justice Ministry. C/José Echegaray, 4, 28232, Las Rozas de Madrid, Madrid, Spain 
2 Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering; University Institute of Research in Police Sciences (IUICP); and CINQUIFOR# research group, University of Alcalá, Ctra, Madrid-Barcelona km 33.600, 28871 Alcalá de Henares, Madrid, Spain 
3 Department of Analytical Chemistry, University of Murcia, 30100 Murcia, Spain 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Riassunto

Aim

The objectives, besides the identification of 4-Bromo-2,5-Dimethoxyphenylethylamine (2C-B) in at least 8 cases of hair, is to evaluate the additional presence of positional isomers obtained by chemical positional derivations, such as 2-Br-4,5-dimethoxyphenylethylamines (2-Br-DMPEA).

Method

A target analysis for hallucinogenic substances confirmation in hair samples by high resolution mass spectrometry (Q-Orbitrap) was performed in the National Institute of Toxicology and Forensic Sciences (INTCF). The method consists in an analysis by LC-HRMS/MS (Q-Orbitrap). It is based on the acquisition of two independent signals: MS-1 and MS-2, as follow, the first one obtained in MS-1 in a full scan mode (FS) analysis, and the second signal was obtained through a MS-2 mode in Parallel Reaction Monitoring (PRM). Only one injection was accomplished. The parameters included in method validation for 2C-B, were: Selectivity (n=10 in ten different hair blanks), matrix effect (ME%) n=10 for each concentration, 20pg/mg (ME=85% RSD%=15.9%, and 200pg/mg (ME=73.6%, RSD%=11%). Limit of detection (LOD=2pg/mg) and limit of quantification (LOQ=5pg/mg), and carryover. Five calibration curves were performed, from 5 to 1000pg/mg range and a lineal mode excluded origin and 1/x factor were applied. Precision (RSD%) and accuracy (E%) were assessed for low, medium and high concentrations, in inter-day conditions (n=15). The values of accuracy and precision were noteworthy according to the acceptance criteria (<15%).

Results

Quantitative results obtained by MS-1 mode for 2C-B in real hair analysis were: from 5.4 to 452.4pg/mg. In five of eight cases only 2C-B was detected. Surprisingly in the other three cases others additional peaks were observed for this precursor. In the scientific literature, at least five positional isomers of 2C-B have been described: 6-Br-2,3-dimethoxyphenylethylamine (DMPEA), 2-Br 3,5-DMPEA, 2-Br 4,5-DMPEA, 5-Br 2,4-DMPEA and 3-Br 2,6-DMPEA. Unfortunately, it is very difficult to obtain these substances as material references certificated (MRC) for being systematically included in our laboratory. At the present moment only 2-Br 4,5-DMPEA was available in the laboratory coming from proficiency test material in matrix of blood. For this reason, only in one of two different positional isomers of 2C-B was detected and it has been able to be compared through the retention time of 2-Br 4,5-DMPEA MRC. Interestingly, the same retention time in real hair case and MRC of 2-Br 4,5-DMPEA were obtained they were coincident. Its retention time was very different in comparison to the retention time of 2C-B eluting-0.7min in advance. Regarding the characteristics of cluster isotopic of the molecule of 2C-B [C10H14BrNO2], the atom of bromine and its isotopes abundance [Br79] and [Br81] is a very specific isotopic pattern. This specific information and fragmentation in source, of primary amine of 2C-B observed in optimization of voltage of s-lens were used for detecting the neutral loss of amine (NH3= 17.0265), in both precursor isomers for Bromine. The identification of 2Br 4,5-DMPEA was compared with MRC from a proficiency test performed last year.

Conclusion

At this moment, there is scarce literature reporting 2C-B consumption through hair analysis. As a consequence the present work shows the highest number of positives in hair samples to the date. The presence of positional isomers of 2C-B that do not coelute (different retention time) with 2C-B can be evaluated in hair analysis of real cases. Interestingly, the hair is an accumulative matrix for a long period and several consumptions can be studied in one aliquot analysis.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2022  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 34 - N° 3S

P. S182 - settembre 2022 Ritorno al numero
Articolo precedente Articolo precedente
  • Biomonitoring of exposure of Algerian population to lead
  • Younes Zebbiche, Ahmed Amziane, Barkahoum Alamir
| Articolo seguente Articolo seguente
  • Authors' index

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.