Abbonarsi

Upper gastrointestinal video capsule endoscopy: The state of the art - 27/03/22

Doi : 10.1016/j.clinre.2021.101798 
Apostolis Papaefthymiou a, b, Apostolos Koffas a, Faidon-Marios Laskaratos c, Owen Epstein d,
a Department of Gastroenterology, General University Hospital of Larisa, Mezourlo, Larisa 41110, Greece 
b First Laboratory of Pharmacology, School of Medicine, Aristotle University of Thessaloniki, 54124 Thessaloniki, Macedonia, Greece 
c Endoscopy Unit, Digestive Diseases Centre, Barking Havering and Redbridge University Hospitals NHS Trust, London, United Kingdom 
d Centre for Gastroenterology, Royal Free Hospital, Pond St, London NW3 2QG, United Kingdom. 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 11
Iconografia 0
Video 0
Altro 0

Abstract

Background

Video capsule can illuminate the entire gastrointestinal mucosa. Upper gastrointestinal capsule endoscopy (UGICE) has the potential to survey for oesophageal, gastric and duodenal pathology and determine whether biopsy or intervention is indicated.

Aims

This review traces the evolution of foregut video capsule endoscopy.

Methods

A broad literature research was performed independently by two investigators. Extracted articles were organized and evaluated to interpret all current data.

Results

In contrast to small bowel capsule, UGICE required sequential innovations to deal with rapid oesophageal transit, the irregular shape of the stomach and unpredictable gastric peristalsis. Oesophageal capsule endoscopy required the development of a two-camera device operating at a high frame rate, and postural change was developed to improve image capture, especially at the level of the Z-line, thus providing good imaging of Barrett's oesophagus, erosive oesophagitis and oesophageal varices, with optimal patients’ tolerance. UGICE in patients presenting to the emergency room with acute bleeding has demonstrated accuracy when deciding on the need for emergency intervention. The latest development of a high frame rate UGICE, designed to image the oesophagus, stomach and duodenum has overtaken dedicated oesophageal capsule development. Capsule control is possible by exposing a magnetised capsule to an external magnetic field, and early reports indicate high accuracy in the oesophagus and stomach with high levels of patient acceptability. There is little information on cost-benefit.

Conclusions

Capsule endoscopy offers gastroenterologists a new device to investigate the upper gastrointestinal tract with promising future potential.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Upper GI endoscopy, Capsule endoscopy

Abbreviations : COVID-19, GORD, GI, MACE, OVCE, OGD, UGIB, UGICE, SBC, SCE, SPIT, VCE


Mappa


 Guarantor of the article: Prof. Epstein is the articles Guarantor.
 Specific author contributions: AP searched the literature, organized the data, wrote the initial draft and reviewed the final manuscript; AK searched the literature, organized the data and reviewed the manuscript; FL reviewed the manuscript; OE conceived the idea, guided the study, and reviewed the manuscript.
 All authors approved the final version of the manuscript.


© 2021  The Authors. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 46 - N° 3

Articolo 101798- Marzo 2022 Ritorno al numero
Articolo precedente Articolo precedente
  • A rare case of duodenal neuroendocrine tumor with hepatic metastasis
  • Ji Li, Wei-Feng Huang, Jin-Yan Zhang
| Articolo seguente Articolo seguente
  • Adipose tissue dysfunction and MAFLD in obesity on the scene of COVID-19
  • Adryana Cordeiro, Amanda Ribamar, Andrea Ramalho

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.