Implementation and evaluation of sepsis surveillance and decision support in medical ICU and emergency department - 09/12/21
Abstract |
Objective |
To improve the timely diagnosis and treatment of sepsis many institutions implemented automated sepsis alerts. Poor specificity, time delays, and a lack of actionable information lead to limited adoption by bedside clinicians and no change in practice or clinical outcomes. We aimed to compare sepsis care compliance before and after a multi-year implementation of a sepsis surveillance coupled with decision support in a tertiary care center.
Design |
Single center before and after study.
Setting |
Large academic Medical Intensive Care Unit (MICU) and Emergency Department (ED).
Population |
Patients 18 years of age or older admitted to *** Hospital MICU and ED from 09/4/2011 to 05/01/2018 with severe sepsis or septic shock.
Interventions |
Electronic medical record-based sepsis surveillance system augmented by clinical decision support and completion feedback.
Measurements and main results |
There were 1950 patients admitted to the MICU with the diagnosis of severe sepsis or septic shock during the study period. The baseline characteristics were similar before (N = 854) and after (N = 1096) implementation of sepsis surveillance. The performance of the alert was modest with a sensitivity of 79.9%, specificity of 76.9%, positive predictive value (PPV) 27.9%, and negative predictive value (NPV) 97.2%. There were 3424 unique alerts and 1131 confirmed sepsis patients after the sniffer implementation. During the study period average care bundle compliance was higher; however after taking into account improvements in compliance leading up to the intervention, there was no association between intervention and improved care bundle compliance (Odds ratio: 1.16; 95% CI: 0.71 to 1.89; p-value 0.554). Similarly, the intervention was not associated with improvement in hospital mortality (Odds ratio: 1.55; 95% CI: 0.95 to 2.52; p-value: 0.078).
Conclusions |
A sepsis surveillance system incorporating decision support or completion feedback was not associated with improved sepsis care and patient outcomes.
Il testo completo di questo articolo è disponibile in PDF.Keywords : Sepsis, Shock, Informatics, Data display, Surveillance, Information technology
Mappa
Vol 51
P. 378-383 - Gennaio 2022 Ritorno al numeroBenvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.
Già abbonato a @@106933@@ rivista ?