Abbonarsi

Association of kidney function and atrial fibrillation progression to clinical outcomes in patients with cardiac implantable electronic devices - 29/09/21

Doi : 10.1016/j.ahj.2021.06.002 
Karolina Szummer, MD PhD a, b, c, Krishna Pundi, MD b, c, Alexander C. Perino, MD b, c, Jun Fan, MSc c, Mitra Kothari, MBBS MPH c, Mintu P. Turakhia, MD MAS b, c,
a Karolinska University Hospital, Theme Heart and Vessel; Karolinska Institutet, Medicine (H7), Stockholm, Sweden 
b Department of Cardiovascular Medicine, Stanford University School of Medicine, Stanford, California 
c Veterans Affairs Palo Alto Health Care System, Palo Alto, California 

Reprint requests: Mintu Turakhia, MD, MAS, Department of Cardiovascular Medicine, Stanford University School of Medicine, Palo Alto VA Health Care System, 3801 Miranda Ave, 111C, Palo Alto, CA 94304Stanford University School of Medicine, Palo Alto VA Health Care System3801 Miranda Ave, 111CPalo AltoCA94304

Riassunto

Background

Kidney function may promote progression of AF.

Objective

We evaluated the association of kidney function to AF progression and resultant clinical outcomes in patients with cardiac implantable electronic devices (CIED).

Methods

We performed a retrospective cohort study using national clinical data from the Veterans Health Administration linked to CIED data from the Carelink® remote monitoring data warehouse (Medtronic Inc, Mounds View, MN). All devices had atrial leads and at least 75% of remote monitoring transmission coverage. Patients were included at the date of the first AF episode lasting ≥6 minutes, and followed until the occurrence of persistent AF in the first year, defined as ≥7 consecutive days with continuous AF. We used Cox regression analyses with persistent AF as a time-varying covariate to examine the association to stroke, myocardial infarction, heart failure and death.

Results

Of, 10,323 eligible patients, 1,771 had a first CIED-detected AF (mean age 69 ± 10 years, 1.2% female). In the first year 355 (20%) developed persistent AF. Kidney function was not associated with persistent AF after multivariable adjustment including CHA2DS2-VASc variables and prior medications. Only higher age increased the risk (HR: 1.37 per 10 years; 95% CI:1.22-1.54). Persistent AF was associated to higher risk of heart failure (HR: 2.27; 95% CI: 1.88-2.74) and death (HR: 1.60; 95% CI: 1.30-1.96), but not stroke (HR: 1.28; 95% CI: 0.62-2.62) or myocardial infarction (HR: 1.43; 95% CI: 0.91-2.25).

Conclusion

Kidney function was not associated to AF progression, whereas higher age was. Preventing AF progression could reduce the risk of heart failure and death.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2021  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 241

P. 6-13 - Novembre 2021 Ritorno al numero
Articolo precedente Articolo precedente
  • Rationale and design of a randomized study comparing the agent drug coated balloon to plain old balloon angioplasty in patients with In-stent restenosis
  • Robert W. Yeh, William Bachinsky, Robert Stoler, Cinthia Bateman, Jennifer A. Tremmel, J. Dawn Abbott, Suhail Dohad, Wayne Batchelor, Paul Underwood, Dominic J. Allocco, Ajay J. Kirtane
| Articolo seguente Articolo seguente
  • Cardiovascular procedural deferral and outcomes over COVID-19 pandemic phases: A multi-center study
  • Celina M. Yong, Kateri J. Spinelli, Shih Ting Chiu, Brandon Jones, Brian Penny, Santosh Gummidipundi, Shire Beach, Alex Perino, Mintu Turakhia, Paul Heidenreich, Ty J. Gluckman

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.