Abbonarsi

Distribution de l’épaisseur cornéenne centrale dans la population tunisienne : étude par tomographie en cohérence optique du segment antérieur - 01/10/19

Distribution of corneal thickness in the Tunisian population: Study by anterior segment optical coherence tomography

Doi : 10.1016/j.jfo.2019.03.017 
M. Ouederni a, , I. Mrad a, H. Sassi a, M. Bellaaj a, H. Letaief b, O. Ayedi a, M. Cheour a
a Faculté de médecine de Tunis, université Tunis El Manar, hôpital Habib Thameur, 3, rue A. Ben Ayed, 1089 Tunis, Tunisie 
b Observatoire national des maladies nouvelles et émergentes, Tunis, Tunisie 

*Auteur correspondant.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Résumé

Objectif

Le but de notre travail est de décrire la distribution de l’épaisseur cornéenne centrale (ECC) dans la population tunisienne.

Méthode

Étude descriptive portant sur les yeux droits de 201 sujets Tunisiens non glaucomateux et en bonne santé choisis au hasard. Tous les sujets ont eu une mesure de la réfraction automatique, une mesure de la longueur axiale par échographie en mode A et une imagerie par tomographie en cohérence optique du segment antérieur (DRI TRITON OCT) afin de déterminer la valeur de l’épaisseur cornéenne centrale.

Résultats

Nous avons examiné un total de 201 yeux. Les sujets examinés étaient âgés entre 18 et 77 ans avec une moyenne de 47±13,5 ans. Le sexe ratio H/F était de 0,46 avec 137 femmes et 64 hommes. Nous avons noté une ECC moyenne de 508,1μm avec un écart type de 31,5μm. Les valeurs variaient entre 440 et 600μm. Dans notre population 43,8 % des sujets avaient une ECC inférieure à 500μm et 89,1 % avaient une ECC inférieure à 550μm. Il n’y avait pas de corrélation statistiquement significative entre l’ECC et l’âge, le sexe, la réfraction automatique en équivalent sphérique et la longueur axiale.

Conclusion

L’épaisseur cornéenne centrale chez les Caucasiens Tunisiens est plus mince que chez les Européens et les Asiatiques. Elle est indépendante de l’âge, du sexe, de la réfraction automatique et de la longueur axiale. Ces données restent à confirmer par des études multicentriques à plus large échelle.

Il testo completo di questo articolo è disponibile in PDF.

Summary

Goals

To describe the distribution of the central corneal thickness (CCT) in the Tunisian population.

Methods

A prospective descriptive study was performed in 201 right eyes of 201 randomly selected healthy Tunisian subjects without glaucoma. We measured the spherical error by autorefraction, the axial length using A-scan ultrasound biometry and the central corneal thickness using anterior segment optical coherence tomography (DRI TRITON OCT).

Results

We examined 201 eyes. The mean age was 47±13.5 years (18 to 77 years). The M/F sex ratio was at 0.46 (137 women and 64 men). The mean CCT was 508,1μm (standard deviation 31,5μm) and ranged from 440 to 600μm. In our population 43.8% had a CCT less than 500μm, and 89.1% had a CCT less than 550μm. No statistically significant correlation was observed between CCT and age, sex, spherical error or axial length.

Conclusion

Central corneal thickness in the Caucasian Tunisian population is less than CCT in the European and Asian populations. CCT is independent of age, sex, spherical error or axial length. These results must be confirmed by larger multicentric studies.

Il testo completo di questo articolo è disponibile in PDF.

Mots clés : Épaisseur cornéenne, Variabilité, Tomographie en cohérence optique, Segment antérieur, Tunisiens

Keywords : Central corneal thickness, Variability, Anterior segment, Optical coherence tomography, Tunisian


Mappa


© 2019  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 42 - N° 8

P. 874-879 - ottobre 2019 Ritorno al numero
Articolo precedente Articolo precedente
  • Eye injury and demographic parameters associated with poor visual outcome
  • N. Jovanovic, C. Peek-Asa, T. Young, F. Nisic, S. Musa
| Articolo seguente Articolo seguente
  • Impact de l’instillation de collyres mydriatiques sur la mesure d’acuité visuelle de loin chez des patients présentant une DMLA exsudative
  • D. Haution, E. Lala, M.L. Le Lez, N. Laube, C. Serrhini, M. Jean-Lechner, M. Dorvault, P.-J. Pisella

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.