La prothèse fémorale Esop revêtue d'hydroxyapatite à modularité métaphysodiaphysaire - 27/03/08

Doi : RCO-05-2007-93-3-0035-1040-101019-200520007 

S. Naudi [1],

N. Mehdi [1],

G. Dauplat [1],

V. Staquet [1],

H. Mestdagh [1],

C. Maynou [1]

Mostrare le affiliazioni

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 8
Iconografia 6
Video 0
Altro 0

Le principe de stabilité primaire et secondaire de la prothèse Esop repose sur un ancrage métaphysaire exclusif, non cimenté. Cet implant modulaire est composé d'une métaphyse revêtue d'hydroxyapatite, sur laquelle est adaptée en peropératoire une pièce diaphysaire jouant un rôle de simple centreur. L'objectif de cette étude rétrospective continue était d'évaluer les stabilités primaire et secondaire de l'implant Esop en mesurant la migration axiale au cours du temps.

Entre 1995 et 2001, 172 PTH utilisant l'implant Esop et l'implant acétabulaire Atlas III, ont été implantées dans notre service. Après exclusion des patients décédés et perdus de vue nous avons revu 155 PTH chez 66 femmes et 32 hommes, d'âge moyen 57 ans, dont 53 % exerçaient une activité professionnelle au moment de l'intervention. La coxarthrose et l'ostéonécrose aseptique représentaient 87 % des étiologies.

Nous avons mesuré à l'aide du logiciel Imagika la migration axiale et l'offset global des PTH à 4 périodes distinctes. Nous avons également analysé la survie et les résultats cliniques et radiographiques de cette série grâce aux scores PMA.

Le taux de survie des PTH de notre série était de 97,81 % (IC à 95 % [7,77 ; 8,03]), toutes causes confondues. Le score PMA retrouvait 97 % de résultats excellents, très bons ou bons.

Une migration de plus de 5 mm a été mise en évidence dans 10 cas (6,4 %). Sur ces 10 cas, 7 avaient migré dans le premier mois, puis n'avaient pas évolué lors de la révision. L'offset fémoral global était diminué de plus de 10 mm dans 38 % des cas, témoignant de la médialisation du centre de rotation de la hanche.

La stabilité primaire et secondaire de l'implant Esop est satisfaisante. La migration observée sur 10 implants correspondait dans 7 cas à un recalage lors de la remise en charge. Le centre de rotation de la hanche subissait globalement une médialisation : dans ces cas il serait intéressant de disposer d'implants latéralisés.

Hydroxyapatite-coated Esop modular femoral stem: three to ten year outcome in 155 cases

Purpose of the study

Primary and secondary stability of the Esop prosthesis depends exclusively on cementless metaphyseal anchoring. This modular implant is composed of an hydroxyapatite-coated metaphysis on which a diaphyseal piece is added intraoperoperatively simply to act as a centering device. The purpose of this retrospective analysis of a consecutive series was to assess primary and secondary stability of the Esop implant by measuring axial migration over time.

Material and methods

Between 1995 and 2001, 172 primary total hip arthroplasties (THAs) were performed with the Esop femoral implant and the Atlas III acetabular implant. Six patients lost to follow-up and eleven patients who died were excluded from the analysis. The review thus concerned 155 THA in 128 patients (66 women and 32 men), mean age 57 years (age range 28-77 years), 53% with an occupational activity at the time of surgery. Degenerative hip disease and aseptic osteonecrosis were present in 87% of patients. Imagika, a dedicated software, was used to measure axial migration and overall offset of the THA at four distinct times: on the immediate pre- and postoperative films, after introduction of weight-bearing, and at last follow-up (mean 61 months, range 35-114 months). Survival and clinical and radiographic outcome were also assessed with the Postel-Merle-d'Aubigné (PMA) score.

Results

THA survival was 98%, all causes of failure included. The PMA score showed 97% excellent, very good or good outcome. Axial migration greater than 5 mm was demonstrated in ten hips (6.4%). Among these ten, seven exhibited migration during the first month than did not move further up to last follow-up. Comparison between the pre- and postoperative images revealed a 10 mm reduction in offset in 38% of hips, showing that the hip rotation center was medialized.

Discussion

Migration observed in ten implants corresponded to restablization at weight-bearing in seven. There was no correlation with the clinical outcome or poor radiological osteointegration.

Conclusion

Primary and secondary stabilization of the Esop implant is satisfactory. In this series, the rotation center of the hip was globally medialized so that it would be useful to have available lateralized implants.


Mots clés : Arthroplastie , hanche , modulaire , hydroxyapatite

Keywords: Arthroplasty , hip , modularity , hydroxyapatite


Mappa



© 2007 Elsevier Masson SAS. Tous droits réservés.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 93 - N° 3

P. 247-254 - Maggio 2007 Ritorno al numero
Articolo precedente Articolo precedente
  • Computer-assisted surgery for acetabular cup positioning in total hip arthroplasty: comparative prospective randomized study
  • S. Parratte, J.-N. Argenson, X. Flecher, J.-M. Aubaniac
| Articolo seguente Articolo seguente
  • Reprise des descellements acétabulaires aseptiques par cupule non cimentée, vissée et allogreffe morcelée impactée
  • S. Parratte, J.-N. Argenson, X. Flecher, J.-M. Aubaniac

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.