Abbonarsi

Absence d’efficacité de la compression pneumatique dans la thromboprophylaxie des arthroplasties totales de genou à faible risque - 28/01/19

Pneumatic compression device does not show effective thromboprophylaxis following total knee arthroplasty in a low incidence population

Doi : 10.1016/j.rcot.2018.12.002 
Kang-Il Kim a, b, Dong-Kyoon Kim a, , Sang-Jun Song b, Se-Jung Hong a, Dae-Kyung Bae b
a Department of Orthopaedic Surgery, Center for Joint Diseases and Rheumatism, Kyung Hee University Hospital at Gangdong, 892, Dongnam-ro, Gangdong-gu, Seoul, République de Corée 
b Department of Orthopaedic Surgery, College of Medicine, Kyung Hee University Seoul, République de Corée 

Auteur correspondant.

Abstract

Introduction

Purpose of this study was to assess whether the intermittent pneumatic compression (IPC) device would be an effective prophylaxis for deep vein thrombosis (DVT) following total knee arthroplasty (TKA) in a low incidence population.

Hypothesis The mechanical thromboprophylaxis could reduce the incidence of DVT compared to non-prophylaxis group and would have similar efficacy as the chemoprophylaxis following TKA in a low DVT incidence population.

Materials and methods

From January 2009 to June 2016, 1259 elective primary TKA with preoperative diagnosis of primary osteoarthritis in a single institute were enrolled. Patients were divided into three groups: those who were managed with chemoprophylaxis (CPX group, 414 cases), with mechanical prophylaxis (IPC group, 425 cases), or without pharmacological and mechanical prophylaxis (control group, 420 cases). All patients underwent preoperative ultrasonography and computed tomographic venography on postoperative day 6 to assess development of DVT. The incidence of overall, proximal, symptomatic DVT and symptomatic pulmonary embolism (PE) were compared among the groups. Major and minor bleeding complications were also evaluated.

Results

The incidence of overall DVT was 14.8% in control group, 6.3% in CPX group and 11.3% in IPC group respectively and CPX group showed significantly lower incidence than other two groups (p<0.001). The incidence of proximal DVT was 1.9% in control group, 0.7% in CPX group and 0.9% in IPC group respectively (p>0.05). The incidence of symptomatic DVT was 0.7% in control group, 0% in CPX group and 0.7% in IPC group respectively (p>0.05). There was no case of symptomatic PE diagnosed during hospital stay in all patients.

Discussion

Single use of IPC device could not reach significant level of DVT prophylaxis compared to control group and only chemoprophylaxis showed significantly reduce the incidence of overall DVT following TKA. Single use of IPC device does not show effective thromboprophylaxis in a low DVT incidence population.

Level of evidence

III, Case control study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Total knee arthroplasty, Deep vein thrombosis, Pneumatic compression, Chemoprophylaxis, Thromboprophylaxis



 Cet article peut être consulté in extenso dans la version anglaise de la revue Orthopaedics & Traumatology: Surgery & Research sur Science Direct (sciencedirect.com) en utilisant le DOI ci-dessus.


© 2018  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 105 - N° 1

P. 39 - febbraio 2019 Ritorno al numero
Articolo precedente Articolo precedente
  • Technique d’alignement cinématique des prothèses unicompartimentaires médiales Oxford : une étude in vitro
  • Charles Rivière, Ciara Harman, Anthony Leong, Justin Cobb, Cedric Maillot
| Articolo seguente Articolo seguente
  • Facteurs prédictifs de satisfaction du patient après prothèse unicompartimentaire et ostéotomie tibiale dans l’arthrose fémorale tibiale médiale du genou
  • In Jun Koh, Man Soo Kim, Sueen Sohn, Kwang Yun Song, Nam Yong Choi, Hoyoung Jung, Yong In

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.