Blood pressure variability in surgical and intensive care patients: Is there a potential for closed-loop vasopressor administration? - 10/01/19

Doi : 10.1016/j.accpm.2018.11.009 
Joseph Rinehart a, Michael Ma a, Michael David Calderon a, Aurelie Bardaji b, Reda Hafiane b, Philippe Van der Linden c, Alexandre Joosten b, d,
a Department of anesthesiology and perioperative care, university of California Irvine, Orange, 101, the City drive South, California, USA 
b Department of anaesthesiology, erasme university Hospital, université Libre de Bruxelles, Brussels, Belgium 
c Department of anaesthesiology, CHU de Brugmann, université Libre de Bruxelles, Brussels, Belgium 
d Department of anaesthesiology and intensive care, hôpitaux universitaires Paris-Sud, université Paris-Sud, université Paris-Saclay, hôpital de Bicêtre, assistance publique hôpitaux de Paris (AP–HP), 78, rue du Général-Leclerc, 94270 Le Kremlin-Bicêtre, France 

Corresponding author at: department of anaesthesiology and intensive care, hôpitaux universitaires Paris-Sud, université Paris-Sud, université Paris-Saclay, hopital de Bicêtre, assistance Publique hôpitaux de Paris (AP–HP), 78, rue du Général-Leclerc, 94270 Le Kremlin-Bicêtre, France.department of anaesthesiology and intensive care, hôpitaux universitaires Paris-Sud, université Paris-Sud, université Paris-Saclay, hopital de Bicêtre, assistance Publique hôpitaux de Paris (AP–HP)78, rue du Général-LeclercLe Kremlin-Bicêtre94270France

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 3
Iconografia 1
Video 0
Altro 0

Abstract

Blood pressure management in the operating rooms (OR) and intensive care units (ICU) frequently involves manually titrated vasopressor therapy to an optimal range of mean arterial pressure (MAP). Ideally, changes in vasopressor infusion rates have to quickly follow variations in blood pressure measurements. However, such a tightly controlled feedback loop is difficult to achieve. Few studies have examined blood pressure control when vasopressor therapy is administered manually in OR and ICU patients. We extracted MAP data from 3623 patients (2530 from the ORs and 1093 from the ICU) on vasopressors from our electronic medical records. Coefficient of variation (= standard deviation/mean value) *100) was calculated and the values were additionally categorized into different MAP ranges (MAP < 60 mmHg, 60 < MAP < 80 and MAP > 80 mmHg). There was no statistically significant difference between both centres for MAP across all time points (80 ± 12 vs. 80 ± 16, P = 0.996, 95% CI −6 to 6). The coefficients of variation of MAP were 13.7 ± 5.4% and 18.4 ± 9.8% in the OR and in ICU respectively. Patients on vasopressors spent 48.8% treatment time with a MAP between 60 and 80 mmHg (11.2% time with MAP < 60 mmHg, and 40% with MAP > 80 mmHg). These results provide a reasonable baseline from which to establish whether ‘reduced variability’ may be achieved with a closed-loop vasopressor administration system.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Mean arterial pressure, Closed-loop, Hypotension, Hypertension, Vasopressors


Mappa


© 2018  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 38 - N° 1

P. 69-71 - Febbraio 2019 Ritorno al numero
Articolo precedente Articolo precedente
  • Anaesthesia management by residents does not alter the incidence of self-reported anaesthesia awareness: A teaching hospital-based propensity score analysis
  • Aya Takechi, Satoki Inoue, Masahiko Kawaguchi
| Articolo seguente Articolo seguente
  • Acute liver failure and misdiagnosis: Do not forget viral hepatitis E
  • Thomas Laumon, Hélène Dietrich, Laurent Muller, Claire Roger

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.