Abbonarsi

Le centre de rotation influence-t-il la récupération du moment des abducteurs après arthroplastie totale de hanche - 23/11/18

Does hip center location affect the recovery of abductor moment after total hip arthroplasty?

Doi : 10.1016/j.rcot.2018.09.138 
Jun-ichi Fukushi a, b, , Ichiro Kawano c, Goro Motomura b, Satoshi Hamai b, Ken-ichi Kawaguchi c, Yasuharu Nakashima b
a Department of Artificial Joints and Biomaterials, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, 812-8582 Fukuoka, Japan 
b Department of Orthopaedic Surgery Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, 812-8582 Fukuoka, Japan 
c Department of Rehabilitation Medicine, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, 812-8582 Fukuoka, Japan 

Auteur correspondant. Department of Artificial Joints and Biomaterials, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, 812-8582 Fukuoka, Japan.Department of Artificial Joints and Biomaterials, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-kuFukuoka812-8582Japan

Abstract

Background

In total hip arthroplasty (THA), placing the cup in an anatomic position is not always possible in case of deformities related to developmental dysplasia of the hip (DDH). Thus far, the influence of a hip center on the abductor moment after THA has not been clearly elucidated. Therefore, we performed a retrospective study to assess 1) how abductor muscle moment recovers postoperatively in THA and 2) whether acetabular cup position affects the recovery of abductor moment.

Hypothesis

A high hip center affects the recovery of abductor moment of a dysplastic hip after THA.

Patients and methods

We evaluated 100 patients, who underwent unilateral primary THA, at 12 months postoperatively. The study included 86 women and 14 men, with a mean age of 65.5±9.9 years (range, 40 to 86 years). Patients with secondary osteoarthritis due to DDH were included (Crowe 1: 76; Crowe 2: 15, Crowe 3: 9, and Crowe 4: none). A cementless straight stem was implanted in all hips. Hip abductor moment was measured using a belt-stabilized handheld dynamometer. The ratio of moment of the affected side to that of the contralateral side was calculated as moment ratio. The horizontal and vertical centers of rotation (H-COR and V-COR) (with respect to the inter teardrop line) and vertical shift (V-shift) (difference in V-COR between the affected hip and the contralateral normal hip) were determined.

Results

At 6 and 12 months postoperatively, the abductor moment ratios were 95.1 and 94.7%, respectively. Significant negative correlation was observed between the postoperative abductor moment ratio and V-COR at 6 months postoperatively (r=−0.2436, p=0.0238). Significant delay in the recovery of abductor moment ratio was observed in the groups with higher hip center (V-shift>15mm) (odds ratio=12.7; 95% CI, 2.11–232.1, p=0.0034) at 6 months postoperatively, which was fully recovered at 12 months postoperatively.

Discussion

Superior placement of a hip center, more than 15mm above the true hip center, delayed the recovery of abductor muscle moment after THA.

Level of evidence

III, retrospective comparative study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Hip center, Superior placement, Abductor muscle strength, Total hip arthroplasty



 Cet article peut être consulté in extenso dans la version anglaise de la revue Orthopaedics & Traumatology: Surgery & Research sur Science Direct (sciencedirect.com) en utilisant le DOI ci-dessus.


© 2018  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 104 - N° 8

P. 777 - dicembre 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Inégalités de longueur après prothèse totale de hanche : y a-t-il un contrôle satisfaisant des longueurs par voie antérieure sans table orthopédique ? Évaluation par EOS 3D sur 56 cas
  • Paul Lecoanet, Morgane Vargas, Julien Pallaro, Thomas Thelen, Clément Ribes, Thierry Fabre
| Articolo seguente Articolo seguente
  • Couple métal-métal ultamet versus céramique-céramique dans l’arthroplastie totale de hanche. Une même survie, mais un taux d’ostéolyse supérieur. Étude à 8 ans de recul
  • Yoshitoshi Higuchi, Taisuke Seki, Yasuhiko Takegami, Daigo Komatsu, Daigo Morita, Naoki Ishiguro

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.