Abbonarsi

Serum S100 calcium binding protein A4 improves the diagnostic accuracy of transient elastography for assessing liver fibrosis in hepatitis B - 21/02/18

Doi : 10.1016/j.clinre.2017.05.013 
Li-Bo Yan a, 1 , Qing-Bo Zhang b, 1 , Xia Zhu a , Min He a , Hong Tang a,
a Center of Infectious Diseases, West China Hospital, Sichuan University, No. 37 Guo Xue Xiang, Chengdu 610041, People's Republic of China 
b Department of Forensic Pathology, Medical School of Basic and Forensic Sciences, Sichuan University, Chengdu 610041, China 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 8
Iconografia 3
Video 0
Altro 0

Summary

Aim

The diagnostic performance of Fibroscan might be improved when combined with other serum fibrosis related markers. Previous study has demonstrated that S100A4 expression is associated with liver fibrosis in humans with hepatitis. This study aimed to clarify diagnostic accuracy of serum S100A4 levels for significant liver fibrosis in patients with chronic hepatitis B (CHB), and develop a combined algorithm of liver stiffness measurement (LSM) and S100A4 to predict significant liver fibrosis in CHB.

Methods

One hundred and seventy-five CHB patients who had performed liver biopsy were consecutively included. We evaluated serum S100A4 levels, LSM values and other clinically-approved fibrosis scores.

Results

Serum S100A4 level was higher in CHB patients with significant fibrosis, compared to those without [199.58 (33.31–1971.96) vs. 107.15 (2.10–1038.94), P<0.001]. Using receiver-operating characteristic (ROC) analyses, the area under the curves (AUC), sensitivity, specificity and accuracy of S100A4 were found to be 0.749, 62.7%, 75.9% and 0.70 for significant fibrosis (≥Stage 2), respectively. Although not superior to LSM, these results were better than the fibrosis index based on the 4 factor (FIB-4) and the aspartate aminotransferase-to-platelet ratio index (APRI) for significant fibrosis detection. An algorithm consisting of S100A4 and LSM was derived. The AUC, sensitivity, specificity and accuracy of model based on serum S100A4 level and LSM were 0.866, 86.6%, 77.8% and 0.79 for significant fibrosis detection, superior to those based on LSM alone (0.834, 76.1%, 80.7% and 0.76, P=0.041).

Conclusion

Serum S100A4 level was identified as a fibrosis marker of liver fibrosis in patients with CHB. Combining serum S100A4 with LSM improved the accuracy of transient elastography for hepatitis B significant fibrosis detection.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : S100A4, Chronic hepatitis B, Significant fibrosis, Liver stiffness measurement

Abbreviations : CHB, HBV, APRI, FIB-4, LSM, TE, AUC, BMI, ALT, AST, INR, HCC, ROC, AUC, HSCs, α-SMA


Mappa


© 2017  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 42 - N° 1

P. 64-71 - Febbraio 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Characteristics and prevalence of Wilson's disease: A 2013 observational population-based study in France
  • Aurélia Poujois, France Woimant, Solène Samson, Pascal Chaine, Nadège Girardot-Tinant, Philippe Tuppin
| Articolo seguente Articolo seguente
  • Hepatoprotective effects of ethyl pyruvate against CCl4-induced hepatic fibrosis via inhibition of TLR4/NF-?B signaling and up-regulation of MMPs/TIMPs ratio
  • Mingxiao Zhang, Xiaosong Hu, Shuai Li, Chen Lu, Juan Li, Yonghua Zong, Wenqian Qi, Huijun Yang

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.