Abbonarsi

Assessment of changes in cardiac index with calibrated pulse contour analysis in cardiac surgery: A prospective observational study - 28/07/16

Doi : 10.1016/j.accpm.2015.12.010 
Marc-Olivier Fischer a, b, , Olivier Rebet a , Pierre-Grégoire Guinot c, d , Charlotte Lemétayer a , Vladimir Saplacan e , Jean-Louis Gérard a , Jean-Luc Fellahi f, g , Jean-Luc Hanouz a, b , Emmanuel Lorne c, d
for

the French Hemodynamic Team

a Pôle réanimations anesthésie Samu/Smur, CHU de Caen, avenue de la Côte-de-Nacre, CS 30001, 14000 Caen, France 
b EA 4650, université de Caen Basse-Normandie, Esplanade de la Paix, CS 14032, 14000 Caen, France 
c Anesthesiology and Critical Care Department, Amiens University Hospital, avenue René-Laennec, 80054 Amiens, France 
d Inserm U 1088, Jules-Vernes University of Picardy, Centre Universitaire de Recherche en Santé (CURS), chemin du Thil, 80025 Amiens cedex, France 
e Service de chirurgie cardiaque, CHU de Caen, avenue de la Côte-de-Nacre, CS 30001, 14000 Caen, France 
f Service d’anesthésie-réanimation, hôpital cardiologique Louis-Pradel, avenue du Doyen-Lepine, 69677 Lyon, France 
g Faculty of Medicine, University of Lyon 1 Claude-Bernard, 69008 Lyon, France 

Corresponding author. Pôle réanimations anesthésie Samu/Smur, CHU de Caen, avenue de la Côte-de-Nacre, 14000 Caen, France. Tel.: +(33) 2 310 647 36; fax: +33 2 310 651 37.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 7
Iconografia 5
Video 0
Altro 0

Abstract

Objectives

To assess the trending ability of calibrated pulse contour cardiac index (CIPC) monitoring during haemodynamic changes (passive leg raising [PLR] and fluid loading) compared with transpulmonary thermodilution CI (CITD).

Method

Seventy-eight mechanically-ventilated patients admitted to intensive care with calibrated pulse contour following cardiac surgery were prospectively included and investigated during PLR, and after fluid loading. Fluid responsiveness was defined as a15% CITD increase after a 500ml bolus. Areas under the empiric receiver operating characteristic curves (ROCAUC) for changes in CIPC (ΔCIPC) during PLR to predict fluid responsiveness and after fluid challenge to predict an increase at least 15% in CITD after fluid loading were calculated.

Results

Fifty-five patients (71%) were classified as responders, 23 (29%) as non-responders. ROCAUC for ΔCIPC during PLR in predicting fluid responsiveness, its sensitivity, specificity, and percentage of patients within the inconclusive class of response were 0.67 (95% CI=0.55–0.77), 0.76 (95% CI=0.63–0.87), 0.57 (95% CI=0.34–0.77) and 68%, respectively. Bias, precision and limits of agreements and percentage error between CIPC and CITD after fluid challenge were 0.14 (95% CI: 0.08–0.20), 0.26, –0.37 to 0.64 l min−1m−2, and 20%, respectively. The concordance rate was 97% and the polar concordance at 30° was 91%. ROCAUC for ΔCIPC in predicting an increase of at least 15% in CITD after fluid loading was 0.85 (95% CI: 0.76–0.92).

Conclusion

Although ΔCIPC after fluid loading could track the direction of changes of CITD and was interchangeable with bolus transpulmonary thermodilution, PLR could not predict fluid responsiveness in cardiac surgery patients.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Arterial pressure, Cardiac surgery, Fluid responsiveness, Passive leg raising, Pulse contour analysis

Abbreviations : CI, CIPC, CITD, CVP, DAP, ICU, MAP, PP, PLR, ROC, ROCAUC, SAP, SV, SVR


Mappa


© 2016  Société française d'anesthésie et de réanimation (Sfar). Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 35 - N° 4

P. 261-267 - Agosto 2016 Ritorno al numero
Articolo precedente Articolo precedente
  • Oesophageal Doppler to optimize intraoperative haemodynamics during prone position. A randomized controlled trial
  • Julien Picard, Damien Bedague, Pierre Bouzat, Céline Ollinet, Pierre Albaladejo, Jean-Luc Bosson, Jean-François Payen
| Articolo seguente Articolo seguente
  • Under sevoflurane anaesthesia, a reduced dose of neostigmine can antagonize a shallow neuromuscular block: A double-blind, randomised study
  • Alice Preault, Florent Capron, Céline Chantereau, François Donati, Jérôme Dimet

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.