The use of static and dynamic haemodynamic parameters before volume expansion: A prospective observational study in six French intensive care units - 07/06/16

Doi : 10.1016/j.accpm.2015.08.003 
Sébastien Preau a, , Florent Dewavrin b , Vincent Demaeght b , Arnaud Chiche c , Benoît Voisin a , Franck Minacori d , Julien Poissy a , Claire Boulle-Geronimi e , Caroline Blazejewski f , Thierry Onimus a , Alain Durocher a , Fabienne Saulnier a
a Intensive Care Unit, Calmette Hospital, University Hospital of Lille, 59000 Lille, France 
b Intensive Care Unit, General Hospital of Valenciennes, 59300 Valenciennes, France 
c Intensive Care Unit, General Hospital of Tourcoing, 59200 Tourcoing, France 
d Intensive Care Unit, University Hospital of Lomme, 59160 Lomme, France 
e Intensive Care Unit, General Hospital of Douai, 59500 Douai, France 
f Intensive Care Unit, Salengro Hospital, University Hospital of Lille, 59000 Lille, France 

Corresponding author at: Critical care centre, University Hospital of Lille, avenue du Professeur-Emile-Laine, Lille 59037, France. Tel.: +33 3 20 44 40 84; fax: +33 3 20 44 50 94.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 10
Iconografia 1
Video 0
Altro 0

Abstract

Objective

The aim of the present study was to determine the use of static and dynamic haemodynamic parameters for predicting fluid responsiveness prior to volume expansion (VE) in intensive care unit (ICU) patients with systemic inflammatory response syndrome (SIRS).

Methods

We conducted a prospective, multicentre, observational study in 6 French ICUs in 2012. ICU physicians were audited concerning their use of static and dynamic haemodynamic parameters before each VE performed in patients with SIRS for 6 consecutive weeks.

Results

The median volume of the 566 VEs administered to patients with SIRS was 1000mL [500–1000mL]. Although at least one static or dynamic haemodynamic parameter was measurable before 99% (95% CI, 99%–100%) of VEs, at least one them was used in only 38% (95% CI, 34%–42%) of cases: static parameters in 11% of cases (95% CI, 10%–12%) and dynamic parameters in 32% (95% CI, 30%–34%). Static parameters were never used when uninterpretable. For 15% of VEs (95% CI, 12%–18%), a dynamic parameter was measured in the presence of contraindications. Among dynamic parameters, respiratory variations in arterial pulse pressure (PPV) and passive leg raising (PLR) were measurable and interpretable before 17% and 90% of VEs, respectively.

Conclusions

Haemodynamic parameters are underused for predicting fluid responsiveness in current practice. In contrast to static parameters, dynamic parameters are often incorrectly used in the presence of contraindications. PLR is more frequently valid than PPV for predicting fluid responsiveness in ICU patients.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Intensive care, Sepsis, Inflammation, Systemic inflammatory response syndrome, SIRS, Passive leg raising, Respiratory variations

Abbreviations : CO, CVP, GEDV, ICU, IVCV, PAOP, PLR, SIRS, SV, VE, VPP


Mappa


© 2015  Société française d'anesthésie et de réanimation (Sfar). Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 35 - N° 2

P. 93-102 - Aprile 2016 Ritorno al numero
Articolo precedente Articolo precedente
  • Vittel criteria for severe trauma triage: Characteristics of over-triage
  • Jean Cotte, Fredrik Courjon, Sébastien Beaume, Bertrand Prunet, Julien Bordes, Cédric N’Guyen, Claire Contargyris, Guillaume Lacroix, Ambroise Montcriol, Eric Kaiser, Eric Meaudre
| Articolo seguente Articolo seguente
  • How to rationalize preoperative tests? A method to implement local guidelines successfully
  • Stéphanie Suria, Hakim Harkouk, Alexandre Eghiaian, Grégoire Weil

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.