Suscribirse

Mobile-bearing versus fixed-bearing total knee implants. Results of a series of 100 randomised cases after 9 years follow-up - 18/05/15

Doi : 10.1016/j.otsr.2015.03.004 
N. Poirier a, b, , P. Graf c, F. Dubrana a, b
a Faculty of Medicine, université de Bretagne-Occidentale, 22, avenue Camille-Desmoulins, CS 93837, 29238 Brest cedex 3, France 
b Department of Orthopaedic Surgery, CHRU de Brest, boulevard Tanguy-Prigent, 29200 Brest, France 
c Clinique Pasteur-Lanroze, 32, rue Auguste-Kervern, 29200 Brest, France 

Corresponding author. Faculty of Medicine, université de Bretagne-Occidentale, 22, avenue Camille-Desmoulins, CS 93837, 29238 Brest cedex 3, France. Tel.: +33 6 80 41 70 29.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Hypothesis

Mobile-bearing total knee arthroplasty (TKA) implants were developed as an alternative to fixed-bearing implants because of their theoretical advantages related to wear and range of motion. For all that, none of the short-term and medium-term studies published so far have reported a significant clinical improvement related to these mobile bearings. The goal of this study was to compare the outcomes of fixed and mobile bearings in the same type of TKA model after a longer follow-up.

Material and methods

This series initially comprised 100 patients with a mean age of 73years who were operated by a single surgeon. The patients were randomised to receive either a fixed bearing TKA implant or a mobile one; their outcomes evaluated after a mean of 9years (7.2–12.2) follow-up. Twenty-two patients died before the final review, 15 were lost to follow-up and 2 were excluded. This resulted in 30 patients with a mobile-bearing knee and 31 with a fixed-bearing knee being available for analysis.

Results

There were no significant clinical differences between the groups receiving a fixed or mobile bearing in terms of the range of motion, subjective outcomes or validated outcomes measured, such as the self-reported Oxford or the IKS. Conversely, there was a significantly higher rate of osteolysis in the fixed-bearing group, but it was not clinically relevant.

Conclusion

This study, which has the longest published follow-up, confirms the results found in the seven randomised studies published up to now: there are no significant differences in the clinical outcomes between fixed-bearing and mobile-bearing inserts of the same TKA model. Although the mobile bearing knees had a better radiographic appearance, this did not translate to better clinical outcomes. In practice, the superiority of mobile bearings is solely theoretical.

Level of evidence II

Prospective randomised study.

El texto completo de este artículo está disponible en PDF.

Keywords : Arthroplasty, Total knee replacement


Esquema


 Based on the Round Table: TKA revision.


© 2015  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 101 - N° 4S

P. S187-S192 - juin 2015 Regresar al número
Artículo precedente Artículo precedente
  • Contents
| Artículo siguiente Artículo siguiente
  • Monopolar-probe monitoring during spinal surgery with expandable prosthetic ribs
  • C. Gomes, M. Kuchenbuch, G. Lucas, P. Sauleau, P. Violas

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.