Suscribirse

Does the PFNA™ nail limit impaction in unstable intertrochanteric femoral fracture? A 115 case-control series - 07/02/15

Doi : 10.1016/j.otsr.2014.11.009 
M. Hélin a, b, A. Pelissier a, b, P. Boyer a, b, T. Delory c, C. Estellat c, P. Massin a, b,
a Département de chirurgie orthopédique, hôpitaux universitaires Paris Nord Val-de-Seine, site Bichat, 46, rue Henri-Huchard, 75877 Paris cedex 18, France 
b Université Paris Diderot, Sorbonne Paris Cité, EA REMES, 75010 Paris, France 
c Département de biostatistiques, hôpitaux universitaires Paris Nord Val-de-Seine, site Bichat, 46, rue Henri-Huchard, 75877 Paris cedex 18, France 

Corresponding author. Département de chirurgie orthopédique, hôpitaux universitaires Paris Nord Val-de-Seine, site Bichat, 46, rue Henri-Huchard, 75877 Paris cedex 18, France. Tel.: +33 1 40 87 52 23; fax: +33 1 40 87 52 92.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

Femoral neck shortening after dynamic fixation of extra-capsular fracture may impair functional results, but is rarely assessed. The present study measured impaction in stable and unstable fractures (on the Ender classification) treated by PFNA™ nail. The objectives were: 1) to validate the Ender classification to assess fracture stability; 2) to determine whether neck shortening and head purchase quality varied with stability; and 3) to determine the functional impact of femoral neck shortening.

Hypothesis

The study hypothesis was that the PFNA™ nail stabilizes unstable as well as stable fractures.

Materials and Methods

One hundred and fifteen consecutive patients, aged over 70 years, operated on for intertrochanteric fracture using the PFNA™ nail were followed up prospectively for 6 months. Multivariate analysis, including age, gender, assembly quality and body-mass index, was applied to assess the predictive power of the Ender classification with respect to femoral neck shortening. Secondly, patients were grouped according to stable versus unstable fracture (n=70 and 45, respectively), and impaction and femoral head purchase were assessed on a dedicated radiographic protocol. Functional results were assessed on Parker score.

Results

In the unstable fracture group, 3 assembly failures required revision by total hip replacement. Ender grade>2 was significantly predictive of>5mm neck shortening. Neck shortening was greater in unstable fracture: 8.1±8.4mm (range, 4–32mm), versus 2.5±3.7mm (range, 3–14mm) (P=0.0004). Mean blade cut-through was 1.2±2.9mm (range, 1–12mm) in unstable fracture, versus 0.3±1.3mm (range, 1–6mm) (P=0.02). Mean cut-out was 2.3±6mm (range, 2–21mm) in unstable fracture, versus 0.5±2.6mm (range, 1–8mm) (P=0.03). Parker scores diminished comparably in the two groups, without significant difference at follow-up: 3.9±2.6 (range, 0–9) in stable and 3.1±1.9 (range, 0–8) in unstable fracture; reduction in Parker score showed no correlation with femoral neck shortening (r=0.013, P=0.88).

Discussion

The PFNA™ nail provides poorer stabilization of unstable compared to stable fracture. Femoral neck shortening should be taken into account in assessing internal fixation hardware perfomances.

Level of evidence

Level III. Prospective case-control study.

El texto completo de este artículo está disponible en PDF.

Keywords : Intertrochanteric fracture, Internal fixation, O.R.I.F unstable fracture, Secondary displacement, Fixation failure


Esquema


© 2014  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 101 - N° 1

P. 45-49 - février 2015 Regresar al número
Artículo precedente Artículo precedente
  • Effectiveness and safety of the posterior approach with soft tissue repair for primary total hip arthroplasty: A meta-analysis
  • D. Zhang, L. Chen, K. Peng, F. Xing, H. Wang, Z. Xiang
| Artículo siguiente Artículo siguiente
  • Evolution of slipped capital femoral epiphysis after in situ screw fixation at a mean 11 years’ follow-up: A 222 case series
  • E. Nectoux, J. Décaudain, F. Accadbled, A. Hamel, N. Bonin, P. Gicquel, French society of Orthopedic, Traumatologic Surgery (SoFCOT) f

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.