Suscribirse

Injury to the axillary nerve after reverse shoulder arthroplasty: An anatomical study - 04/02/14

Doi : 10.1016/j.otsr.2013.09.006 
A. Lädermann a, b, c, , B.V. Stimec d, P.J. Denard e, f, G. Cunningham c, P. Collin g, J.H.D. Fasel d
a Division of Orthopedics and Trauma Surgery, La Tour Hospital, 3, rue J.-D.-Maillard, 1217 Meyrin, Switzerland 
b Faculty of Medicine, University of Geneva, 1, rue Michel-Servet, 1211 Geneva 4, Switzerland 
c Division of Orthopedics and Trauma Surgery, Department of Surgery, Geneva University Hospitals, 4, rue Gabrielle-Perret-Gentil, 1211 Geneva 21, Switzerland 
d Faculty of Medicine, Department of Cellular Physiology and Metabolism, Anatomy Sector, University of Geneva, 1, rue Michel-Servet, 1211 Geneva 4, Switzerland 
e Southern Oregon Orthopedics, Medford, Oregon, USA 
f Department of Orthopedics and Rehabilitation, Oregon Health & Science University, Portland, Oregon, USA 
g Saint-Grégoire Private Hospital Center, 6, boulevard Boutière, 35768 Saint-Grégoire cedex, France 

Corresponding author. Division of Orthopedics and Trauma Surgery, La Tour Hospital, 3, rue J.-D.-Maillard, 1217 Meyrin, Switzerland. Tel.: +41 22 719 75 55; fax: +41 22 719 60 77.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Background

Subclinical neurological lesions after reverse shoulder arthroplasty are frequent, mainly those involving the axillary nerve. One of the major reported risk factors is postoperative lengthening of the arm. The purpose of this study was to evaluate the anatomical relationship between the axillary nerve and prosthetic components after reverse shoulder arthroplasty. The study hypothesis was that inferior overhang of the glenosphere relative to glenoid could put this nerve at risk.

Material and methods

Eleven fresh frozen shoulder specimens were dissected after having undergone reverse shoulder arthroplasty using a classic deltopectoral approach.

Results

The mean distance from the inferior border of the glenoid to the inferior edge of the glenosphere was 6.0±4.3mm (range, 1.0 to 16.2mm). The axillary nerve was never closer than 15mm to the glenosphere. The main anterior branch of the axillary nerve was in close contact with the posterior metaphysis or humeral prosthetic implant. The mean distance between the nerve and the humeral implants was 5.2±2.1mm (range, 2.0 to 8.1mm).

Conclusions

The proximity of the axillary nerve to the posterior metaphysis or humeral implants may be a risk factor for axillary nerve injury after reverse shoulder arthroplasty.

Clinical relevance

This study quantifies the proximity of the axillary nerve to the implant after reverse shoulder arthroplasty.

Level of evidence

Basic science study, cadaver study.

El texto completo de este artículo está disponible en PDF.

Keywords : Axillary nerve lesion, Reverse shoulder arthroplasty, Complications, Prosthesis


Esquema


© 2013  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 100 - N° 1

P. 105-108 - février 2014 Regresar al número
Artículo precedente Artículo precedente
  • Validity, reliability and responsiveness of the French language translation of the Western Ontario Shoulder Instability Index (WOSI)
  • C. Gaudelli, F. Balg, V. Godbout, S. Pelet, A. Djahangiri, S. Griffin, D.M. Rouleau
| Artículo siguiente Artículo siguiente
  • Does bone density of the greater tuberosity change in patients over 70?
  • P. Clavert, J. Bouchaïb, C. Sommaire, P.-H. Flurin, P. Hardy, SFA d

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.