Suscribirse

Thigh pain, subsidence and survival using a short cementless femoral stem with pure metaphyseal fixation at minimum 9-year follow-up - 02/02/13

Doi : 10.1016/j.otsr.2012.09.016 
G. Cinotti , A. Della Rocca, P. Sessa, F.R. Ripani, G. Giannicola
Orthopaedic Department, La Sapienza University, Piazzale Aldo Moro, 500185 Rome, Italy 

Corresponding author. Department of Anatomy, Histology, Medico Legal and Orthopaedic Sciences, La Sapienza University, 5, Piazzale Aldo Moro, 00185 Rome, Italy. Tel.: +347 8419319; fax: +06 6896088.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Summary

Background

Short femoral stems designed to spare bone stock and improve load transfer at the proximal femur level have been introduced in recent years. However, little is known on the long-term outcomes of these stems.

Hypothesis

Short cementless stems have low rate of thigh pain and subsidence as well as few revision needs at mid-term follow-up.

Materials and methods

We prospectively followed 64 patients (72 hips) undergoing total hip arthroplasty with a femoral stem designed to achieve a pure metaphyseal fixation. Patients with hip fracture, femoral neck deformity and osteoporotic bone were excluded. Clinical evaluations were performed annually until the last follow-up, a minimum of 9 years after surgery. At each follow-up, implant positioning was assessed on conventional plain films with a computer assisted radiographic evaluation.

Results

The Harris hip score improved from 43 points (range 19–50) before surgery to 88 points (range 73–100) at the final follow-up (P=0.001), and the Womac score averaged 47 points (range 35–56 points) preoperatively and 76 points (range 63–84) at the last follow-up (P=0.001). Thigh pain was reported by five patients (8%) at the 2-year follow-up, but only in two (3%) was still present, and related to the prosthesis, at last follow-up. Computer assisted radiographic analysis showed a neutral alignment of the stem in 56% of cases, a varus-valgus alignment less than 5° in 36% and equal to 5° in 8%. Stem subsidence was observed in 12 hips but was less than 4mm in all cases (range 0–3mm). Calcar height remained unchanged over time. Adaptive bone remodelling, including proximal bone resorption and distal cortical hypertrophy were not observed at follow-up. No patients had aseptic loosening of the stem nor were radiolucent lines detectable at the level of the porous coating. Survivorship analysis showed a 100% survival rate of the stem at nine years.

Discussion

This study showed that a femoral stem designed to achieve a pure metaphyseal fixation may obtain, in a selected group of patients with adequate bone quality, satisfactory clinical outcomes without compromising implant stability. The limited periprosthetic bone remodelling observed after a minimum of 9 years follow-up suggests that this type of implant may improve mechanical stresses on host bone compared with standard stems requiring diaphyseal fixation.

Level of evidence

Level IV. Historical series.

El texto completo de este artículo está disponible en PDF.

Keywords : Total hip arthroplasty, Femoral stem, Proximal fixation, Bone remodeling, Thigh pain


Esquema


© 2012  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 99 - N° 1

P. 30-36 - février 2013 Regresar al número
Artículo precedente Artículo precedente
  • Three-dimensional finite element analysis of mini-external fixation and Kirschner wire internal fixation in Bennett fracture treatment
  • L. Meng, Y. Zhang, Y. Lu
| Artículo siguiente Artículo siguiente
  • The prevalence of acetabular anomalies associated with pistol-grip-deformity in osteoarthritic hips
  • I. Ipach, F. Mittag, C. Walter, R. Syha, P. Wolf, T. Kluba

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.