Suscribirse

Différences induites par la définition des périodes diurnes et nocturnes sur la pression artérielle et le dipping lors d’une mesure ambulatoire de la pression artérielle - 24/08/12

Doi : 10.1016/j.ancard.2012.04.016 
M.-E. Muller a, M. Bochud b, M. Pruijm a, K. Iglesias b, c, M. Burnier a, G. Wuerzner a, , c
a Service de néphrologie et d’hypertension, CHU Vaudois, rue du Bugnon 17, 1011 Lausanne, Suisse 
b Institut universitaire de médecine sociale et préventive, Lausanne, Suisse 
c Centre de recherche clinique, CHU Vaudois, Lausanne, Suisse 

Auteur correspondant.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

páginas 5
Iconografías 2
Vídeos 0
Otros 0

Résumé

La mesure ambulatoire de la pression artérielle (MAPA) est devenue un outil indispensable dans le diagnostic et le contrôle de la pression artérielle (PA). Il n’existe cependant aucun consensus concernant la définition des périodes diurnes ou nocturnes lors des MAPA.

But de l’étude

Comparer les valeurs de PA diurnes et nocturnes et la baisse nocturne de la PA (dipping) définies par un actigraphe et par la position du corps aux valeurs calculées sur des périodes fixées arbitrairement.

Patients et méthodes

Enregistrement simultané de la MAPA, des périodes de sommeil et de la position du corps (débout/allongé) par un actigraphe (SenseWear Armband®) chez des patients référés pour une MAPA. Les résultats obtenus par l’actigraphe (sommeil et position) étaient comparés aux résultats obtenus par une période de jour (07h00–22h00) et de nuit (22h00–07h00) fixées arbitrairement.

Résultats

Les données de 103 patients, dont plus de la moitié étaient traités pour une hypertension, ont été analysées. Par rapport aux périodes fixées arbitrairement, les PA nocturnes étaient plus basses (PA systolique : 2,08±4,50mmHg ; PA diastolique : 1,84±2,99mmHg, p<0,05) et le dipping était plus marqué (PA systolique : 1,54±3,76 % ; PA diastolique : 2,27±3,48 %, p<0,05) lorsque la période nocturne était définie par l’actigraphe. Les valeurs en position debout étaient supérieures (PA systolique : 1,07±2,81mmHg ; PA diastolique : 1,34±2,50mmHg) aux valeurs diurnes de la période diurne fixée.

Conclusion

La PA diurne et nocturne ainsi que le dipping sont influencés par la méthode utilisée pour définir l’intervalle nocturne. Le choix d’une méthode par rapport à une autre dépendra de la valeur pronostique de chaque méthode sur des évènements cardiovasculaires.

El texto completo de este artículo está disponible en PDF.

Abstract

Ambulatory blood pressure monitoring (ABPM) has become indispensable for the diagnosis and control of hypertension. However, no consensus exists on how daytime and nighttime periods should be defined.

Objective

To compare daytime and nighttime blood pressure (BP) defined by an actigraph and by body position with BP resulting from arbitrary daytime and nighttime periods.

Patients and method

ABPM, sleeping periods and body position were recorded simultaneously using an actigraph (SenseWear Armband®) in patients referred for ABPM. BP results obtained with the actigraph (sleep and position) were compared to the results obtained with fixed daytime (7a.m.–10p.m.) and nighttime (10p.m.–7a.m.) periods.

Results

Data from 103 participants were available. More than half of them were taking antihypertensive drugs. Nocturnal BP was lower (systolic BP: 2.08±4.50mmHg; diastolic BP: 1.84±2.99mmHg, P<0.05) and dipping was more marked (systolic BP: 1.54±3.76%; diastolic BP: 2.27±3.48%, P<0.05) when nighttime was defined with the actigraph. Standing BP was higher (systolic BP 1.07±2.81mmHg; diastolic BP: 1.34±2.50mmHg) than daytime BP defined by a fixed period.

Conclusion

Diurnal BP, nocturnal BP and dipping are influenced by the definition of daytime and nighttime periods. Studies evaluating the prognostic value of each method are needed to clarify which definition should be used.

El texto completo de este artículo está disponible en PDF.

Mots clés : Hypertension, Mesure ambulatoire de la pression artérielle, Dipping, Actigraphe

Keywords : Hypertension, Ambulatory blood pressure monitoring, Actigraph, Dipping


Esquema


© 2012  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 61 - N° 3

P. 193-197 - juin 2012 Regresar al número
Artículo precedente Artículo precedente
  • Une nouvelle méthode spontanée pour l’évaluation du baroréflexe sympathique chez l’Homme
  • C. Gallet, M. Gujic, D. Laude, P. van de Borne, C. Julien
| Artículo siguiente Artículo siguiente
  • Influence de la variabilité de la pression artérielle en consultation sur le diagnostic du contrôle tensionnel chez des hypertendus traités
  • F. Villeneuve, D. Rosenbaum, C. Gury, X. Girerd

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
La compra de artículos no está disponible en este momento.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.