Suscribirse

Functional performance after hip resurfacing or total hip replacement: A comparative assessment with non-operated subjects - 07/02/12

Doi : 10.1016/j.otsr.2011.10.006 
C. Szymanski a, , R. Thouvarecq e, F. Dujardin b, H. Migaud d, C. Maynou a, J. Girard c, d
a Orthopedics A, Roger-Salengro Hospital, Lille Regional University Hospital Center, 2, avenue Oscar-Lambret, 59037 Lille cedex, France 
b Orthopedic Dept, Charles-Nicolle Hospital, Félix-Dévé-Ward, Rouen Regional University Hospital Center, 1, rue de Germont, 76031 Rouen, France 
c Medicine and Sports Center, Lille-2 Medical School, Lille Nord-de-France University, 59045 Lille cedex, France 
d Orthopedics C, Roger-Salengro Hospital, Lille Regional University Hospital Center, 2, avenue Oscar-Lambret, 59037 Lille cedex, France 
e Rouen CETAPS, Sports Science and Physical Education Faculty, boulevard Siegfried, 76821 Mont-Saint-Aignan cedex, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Summary

Introduction

Several studies reported better clinical results with total hip resurfacing than with conventional total hip replacement, including in young patients, but without comparative stabilometry assessment.

Hypothesis

Resurfacing arthroplasty provides better functional performance than conventional total hip replacement.

Objectives

To test the above hypothesis in a stabilometry study comparing balance and functional performance in patients with total hip resurfacing or conventional total hip replacement and healthy controls.

Materials and methods

Results were analyzed on three cohorts of 20 patients: healthy control subjects, with unilateral total hip replacement or unilateral total hip resurfacing. The 40 operated patients were comparable in gender, age, weight (body-mass index), date of operation and clinical results. The 20 control subjects were younger and served as reference. Balance analysis employed a force platform commonly used in stabilometry, standardizing both leg or single leg stance balance analysis. The software interpreted individual balance by measuring plantar pressure center variation during the analysis so as to contour an individual both leg or single leg area of balance (statokinesigram, in mm2).

Results

Balance analysis on both leg found comparable results in the control and resurfacing groups. The weight-bearing statokinesigraphic both leg balance area was greater in the hip replacement than in either of the other two groups (p<0.05), and five times greater than in the resurfacing group (p<0.05). The single leg weight-bearing balance results were significantly better in the resurfacing group, with a statokinesigraphic balance area half that of the hip replacement group, whether on the operated or the non-operated side (p<0.001).

Discussion and conclusion

The present functional performance results confirm the advantage of resurfacing over conventional hip replacement, and help explain the excellent radioclinical results reported for total hip resurfacing.

Level of evidence

III, comparative case-control study.

El texto completo de este artículo está disponible en PDF.

Keywords : Hip resurfacing, Proprioception, Functional performance, Hip


Esquema


© 2012  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 98 - N° 1

P. 1-7 - février 2012 Regresar al número
Artículo precedente Artículo precedente
  • Contents
| Artículo siguiente Artículo siguiente
  • Functional recovery, complications and CT positioning of total hip replacement performed through a Röttinger anterolateral mini-incision. Review of a continuous series of 103 cases
  • C. Mandereau, V. Brzakala, J. Matsoukis

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.