Interprosthetic femoral fractures: Analysis of 14 cases. Proposal for an additional grade in the Vancouver and SoFCOT classifications - 26/10/11

Doi : 10.1016/j.otsr.2011.07.009 
M. Soenen a, , b , H. Migaud b, F. Bonnomet c, J. Girard b, H. Mathevon d, M. Ehlinger c
a Europe Private Hospital, 61, boulevard de l’Europe, 76100 Rouen, France 
b Orthopedics department C, Roger Salengro Hospital, Lille University Hospital, 59037 Lille cedex, France 
c Orthopedic and Traumatologic Surgery Department, Hautepierre Hospital, Strasbourg University Hospitals, 1, avenue Molière, 67098 Strasbourg cedex, France 
d Orthopedics and Traumatology Department, 130, avenue Louis-Herbeaux, 59240 Dunkerque, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Summary

Introduction

Interprosthetic fracture is a rare but serious entity, impairing consolidation and stability due to adverse mechanical conditions related to bone fragility and implant volume.

Objective

The present study highlights the difficulties involved in managing such fractures, details treatment options and reports findings leading to a proposed additional grade in the comparable Vancouver (hip) and French Orthopedic and Traumatologic Surgery Society (Société française de chirurgie orthopédique et traumatologique: SoFCOT) (knee) classification systems.

Patients and methods

A multicenter retrospective series included 14 interprosthetic femoral fractures: eight type double C (typeC for both hip and knee), five type C for hip and B for knee, and one type double B (type B for both hip and knee) on the Vancouver and SoFCOT classifications. Fracture occurred on standard (n=15) or revision (n =13) implants. Six cases involved a femoral shaft encumbered by a total knee replacement (TKR) femoral extension stem and eight cases TKR without femoral long stem, assimilable to type C fracture.

Results

None of the six fractures proximal to a constrained TKR with stem-achieved union by primary intention, whereas seven of the eight type-C fractures did so. Finally, 12 cases showed favorable evolution, with three secondary total femur replacements (TFR) and one death at 6 months without bony union or revision and one patient waiting for TFR.

Discussion

To describe the status of the intermediate femur and its medullary canal encumbrance, we propose adding a category D to the SoFCOT and Vancouver classifications, corresponding to interprosthetic fracture on TKR with diaphyseal extension stem. Interprosthetic fracture internal fixation should begin with long devices bridging the two prostheses. When the implant is loose, it may be replaced; in case of diaphyseal extension, however, the residual femur between the two extensions should be protected against peak stress by a plate extending upward and downward. In case of limited bone stock, due to osteolysis or initial femoral medullary canal compromise, especially if one or both implants are loose, TFR may be indicated as consolidation, is jeopardized by the uncertain mechanical situation.

Level of evidence

Level IV, retrospective study.

El texto completo de este artículo está disponible en PDF.

Keywords : Femoral fracture, Periprosthetic fracture, Interprosthetic fracture, Osteosynthesis, Internal fixation, Locking compression plate, Total femur replacement


Esquema


© 2011  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 97 - N° 7

P. 693-698 - novembre 2011 Regresar al número
Artículo precedente Artículo precedente
  • Factors governing the healing of Staphylococcus aureus infections following hip and knee prosthesis implantation: A retrospective study of 95 patients
  • D. Joulie, J. Girard, O. Mares, E. Beltrand, L. Legout, H. Dezèque, H. Migaud, E. Senneville
| Artículo siguiente Artículo siguiente
  • Rotational positioning of the tibial tray in total knee arthroplasty: A CT evaluation
  • J. Berhouet, P. Beaufils, P. Boisrenoult, D. Frasca, N. Pujol

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.