Suscribirse

Morphometric analysis and functional correlation of tibial and femoral footprints in anatomical and single bundle reconstructions of the anterior cruciate ligament of the knee - 24/09/11

Doi : 10.1016/j.otsr.2011.07.004 
S. Plaweski , D. Petek, D. Saragaglia
Academic Clinic of Orthopaedic Surgery and Sports Medicine Trauma, South Hospital, Grenoble Teaching Medical Center, 38434 Echirolles, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Summary

Introduction

The anterior cruciate ligament (ACL) is composed of an infinite number of fibers whose individual anatomical and biomechanical features have been well defined. Although numerous biomechanical studies have shown that reconstruction that is as anatomical as possible results in better control of rotational laxity, very few studies have investigated the surface area of tibial and femoral insertion sites in these reconstructions. The aim of this study was to compare the surface areas of tibial and femoral insertion sites in single and double bundle reconstructions and correlate these findings with the isometry profile obtained. Our hypothesis was that double bundle (DB) reconstruction results in better filling of the native ACL footprint thus increasing the biomechanical value of available graft tissue.

Patients and methods

Forty-six patients underwent computer navigated ACL using hamstring tendons: 23 underwent single bundle (SB) and 23 DB reconstruction. The Praxim navigation station equipped with ACL logics software made it possible to digitize insertion site footprints, register perioperative data for graft position as well as anteroposterior and rotational laxities and pivot shift.

Results

There was a statistically significant difference between the two groups for tibial and femoral insertion site surface areas: 71mm2±17 (SB) versus 99.9mm2±30 (DB) for the tibia, 67±11mm2 (SB) versus 96.9mm2±28 (DB) for the femur. Isometry profiles showed that anisometry was favorable in all cases: 2.5mm±2 for SB; 2.9mm±2 for the anteromedial bundle (AMB) with DB and 9.6mm±3.7 for the posterolateral bundle. When both groups were combined, there was a statistically significant correlation between the size of tibial insertion surface area and anteroposterior and rotational laxity.

Discussion

This study confirms that better filling of native ACL footprint surface areas results in better control of anteroposterior laxity.

Level of evidence

Level IV.

El texto completo de este artículo está disponible en PDF.

Keywords : Double bundle anterior cruciate ligament, Single bundle anterior cruciate ligament, ACL reconstruction


Esquema


© 2011  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 97 - N° 6S

P. S75-S79 - octobre 2011 Regresar al número
Artículo precedente Artículo precedente
  • CAOS Editorial Board
| Artículo siguiente Artículo siguiente
  • Analysis of anatomic positioning in computer-assisted and conventional anterior cruciate ligament reconstruction
  • S. Plaweski, J. Rossi, P. Merloz, R. Julliard

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.