Pelvis and total hip arthroplasty acetabular component orientations in sitting and standing positions: Measurements reproductibility with EOS imaging system versus conventional radiographies - 07/06/11

Doi : 10.1016/j.otsr.2011.02.006 
J.Y. Lazennec a, , M.A. Rousseau a, A. Rangel a, M. Gorin b, C. Belicourt a, A. Brusson a, Y. Catonné a
a Department of orthopaedic and trauma surgery, Pitié-Salpêtrière hospital, 47-83, boulevard de l’Hôpital, 75634 Paris cedex 13, France 
b Department of radiography, Foch hospital, 4, rue Worth, 92151 Suresne, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Summary

Introduction

The literature has recently underlined the interest of pelvic and acetabular component orientation measurements in the standing and sitting position. Radiographic follow-up of total hip arthroplasty (THA) is based on standard AP and lateral X-rays. The use of EOS™ 2D imaging system reduces patient’s radiation exposure compared to conventional X-rays. However, using this system, the validity and reproducibility of angular measurements, have not been studied yet for the measurement of pelvic and acetabular parameters in patients with THA.

Hypothesis

The EOS™ 2D imaging system offers similar advantages to conventional X-rays in the measurement of pelvic and acetabular orientation parameters which are commonly used.

Patients and method

Five angular parameters characterizing pelvic tilt and acetabular cup orientation were determined using the same digital measurement Imagika™ software based on two series of standard X-rays and EOS™ 2D images acquired in both standing and sitting positions. Radiographs from 50 patients with unilateral THA were measured three times by two observers. Intra- and interobserver reproducibility using each method was independently studied then paired comparison was performed.

Results

The ICC and Spearman rank correlation coefficient demonstrated an excellent EOS/conventional X-ray correlation. According to the parameters, the mean difference between these two imaging modalities ranged from 0.30° to 3.43° (P<0.05). The intra- and interobserver variability ranged from±2.97° to±6.46° using the EOS™ imaging system and from±4.26° to±10.22° using conventional X-rays (P<0.05).

Discussion

The EOS™ 2D imaging system may replace conventional X-rays in the assessment and monitoring of pelvic and acetabular cup orientation in THA.

Level of evidence

Level III. Prospective diagnostic study.

El texto completo de este artículo está disponible en PDF.

Keywords : EOS measurements, Hip prosthesis, Total hip arthroplasty, Acetabulum, Cup, Pelvis orientation, Anterior pelvic plane


Esquema


© 2011  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 97 - N° 4

P. 373-380 - juin 2011 Regresar al número
Artículo precedente Artículo precedente
  • Can injection CT scan assess the residual femoral head vascularity after acute neck fracture?
  • M. Ehlinger, T. Moser, G. Bierry, P. Adam, J.-P. Armspach, F. Bonnomet, A. Gangi, M. de Mathelin
| Artículo siguiente Artículo siguiente
  • Is a hip distractor useful in the arthroscopic treatment of femoroacetabular impingement?
  • X. Flecher, J. Dumas, J.-N. Argenson

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.