Suscribirse

Tibial component rotation assessment using CT scan in medial and lateral unicompartmental knee arthroplasty - 30/04/11

Doi : 10.1016/j.otsr.2010.11.002 
E. Servien a, , C. Fary d, S. Lustig a, G. Demey a, M. Saffarini b, S. Chomel c, P. Neyret a
a Department of Orthopaedic Surgery, Albert Trillat Medical Center, Croix-Rousse Hospital, Lyon civilian hospices, Lyon 1 University, 103, grande rue de la Croix-Rousse, 69004 Lyon, France 
b Research & Development Department, Tornier SAS, 38330 Saint-Ismier, France 
c Radiology Department, Protestant Infirmary, Lyon-Caluire, France 
d Department of Orthopaedic and Trauma surgery, The Royal Melbourne Hospital, Parkville, 3052 Melbourne (Victoria), Australia 

Corresponding author Tel.: +33 4 26 10 92 51.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Summary

Background

Rotation of tibial component has not been analysed in literature for unicompartmental knee arthroplasty. The purpose of the study was to determine and compare the rotation of medial and lateral unicompartmental knee arthroplasty (UKA) tibial components. We assumed both components (lateral and medial) were positioned with external rotation.

Patients and methods

Eighteen lateral and 19 medial UKA patients were scanned postoperatively in neutral position with computed tomography enabling lower extremity three-dimensional image acquisition from the hip to the ankle. All the patients were operated by three different senior surgeons using the same surgical technique. From the reconstructions we measured the two-dimensional (2D) rotation of the tibial components.

Results

The rotation of the tibial component was external (mean 6.5°, SD 5.1°) for the medial UKA and external (mean 7.3°, SD 10.3°) as well for the lateral UKA. The difference was statistically insignificant (P=0.717).

Discussion

This study presents the first 2D in vivo analysis accurately determining and comparing medial and lateral UKA component rotation. Despite a wide range of value, we found both components were indeed externally rotated. The variability in implant positioning was observed despite the rigorous performance of an experienced surgeon using routine techniques in patients selected under routine criteria. Further analysis of these patients for satisfaction and implant survivorship in relation to implant rotation may give us an optimal range for the tibial component. If it is found that this ideal range cannot be consistently obtained with current surgical techniques then there may be a case for the use of a navigation system.

Level of evidence

Level IV retrospective study.

El texto completo de este artículo está disponible en PDF.

Keywords : Unicompartmental, Knee arthroplasty, Component positioning, Rotation, CT scan


Esquema


© 2011  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 97 - N° 3

P. 272-275 - mai 2011 Regresar al número
Artículo precedente Artículo precedente
  • Validation of a French version of the Oxford knee questionnaire
  • J.-Y. Jenny, Y. Diesinger
| Artículo siguiente Artículo siguiente
  • Tibial tubercule osteotomy during medial approach to difficult knee arthroplasties
  • J. Tabutin, N. Morin-Salvo, R. Torga-Spak, P.-M. Cambas, F. Vogt

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.