Is transverse acetabular ligament an anatomical landmark to reliably orient the cup in primary total hip arthroplasty? - 30/04/11

Doi : 10.1016/j.otsr.2010.07.012 
A. Viste a, b, , J. Chouteau a, b, R. Testa a, b, L. Chèze a, M.-H. Fessy a, b, B. Moyen a, b
a IFSTTAR, LBMC UMRT 9406, INRETS, University Lyon 1, 43, Bolevard du 11-Novembre-1918, 69100 Villeurbanne, France 
b Traumatology and Sports Medicine Department, Department of Orthopaedic Surgery–Building 3A, Lyon Civilian Hospices South Lyon Hospital Center, Orthopaedic Surgery, 165, chemin du Grand-Revoyet, 69495 Pierre-Bénite cedex, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Summary

Introduction

Accurate positioning of the acetabular cup in primary total hip arthroplasty is critical to decrease the rate of dislocation. Inaccurate orientation of the cup is the most common error during this procedure. Target acetabular orientation is still controversial. An original study found a dislocation rate of 0.6% when the cup was aligned with the transverse acetabular ligament (TAL).

Hypothesis

TAL is a patient-specific anatomical landmark and a tool for cup orientation.

Materials and methods

Eight cadaveric pelves (14 hips included for study) were harvested in toto at our research laboratory. Anatomical versions of the TAL, labrum and horns were measured in relation to the anterior pelvic plane. A navigator sensor and an optoelectronic device (Motion Analysis™) were used.

Results

Anatomical versions of the TAL, horns and labrum averaged 1.9° (range, −8° to +13.3°), 3° (range, −12.2° to 14°), and 26.3° (range, 17.4° to 41.8°), respectively.

Discussion

To our knowledge, this is the first study to report the orientation of the periacetabular soft-tissues. TAL anteversion was outside the safe zone described by Lewinnek, while labrum anteversion was within this safe-zone. We discuss the reference used, Lewinnek’s safe zone, and functional orientation of the implants. Lewinnek’s safe-zone does not seem to be valid. The TAL seems to be a specific reference for each patient but its reliability must still be confirmed as an adequate reference for positioning the cup in total hip arthroplasty.

Level of evidence

Level IV Prospective study.

El texto completo de este artículo está disponible en PDF.

Keywords : Total hip replacement, Dislocation, Transverse acetabular ligament, Cup orientation


Esquema


© 2011  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 97 - N° 3

P. 241-245 - mai 2011 Regresar al número
Artículo precedente Artículo precedente
  • Radiographic changes of the femoral neck after total hip resurfacing
  • J.-M. Laffosse, K. Aubin, M. Lavigne, A. Roy, P.-A. Vendittoli
| Artículo siguiente Artículo siguiente
  • Acromio humeral distance less than six millimeter: Its meaning in full-thickness rotator cuff tear
  • D. Goutallier, P. Le Guilloux, J.-M. Postel, C. Radier, J. Bernageau, S. Zilber

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.