Suscribirse

Bloc interscalénique échoguidé : variations anatomiques et implication clinique - 23/11/10

Doi : 10.1016/j.annfar.2010.07.013 
C. Gutton a, , O. Choquet a, F. Antonini b, P. Grossi c
a Service d’anesthésie-réanimation, hôpital la Conception, CHU de Marseille, 147, boulevard Baille, 13385 Marseille cedex 5, France 
b Service d’anesthésie-réanimation, hôpital Nord, CHU de Marseille, chemin des Bourrely, 13915 Marseille cedex 20, France 
c Service d’anesthésie locorégionale et de traitement de la douleur, IRCCS Policlinico San Donato, Universita degli studi di Milano, via G. Morandi 30, 20097 San Donato Milanese, Italie 

Auteur correspondant.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

páginas 6
Iconografías 4
Vídeos 0
Otros 0

Résumé

Objectifs

La région interscalénique présente de nombreuses variations anatomiques. L’objectif principal de cette étude est d’évaluer la mise en évidence de ces variations en échographie par l’anesthésiste. L’objectif secondaire est de comparer la réussite du bloc interscalénique (BIS) en présence ou non d’une variation.

Type d’étude

Étude rétrospective, descriptive, conduite dans deux hôpitaux universitaires.

Patients et méthodes

Cent quarante-six échographies de cou réalisées chez 27 volontaires et 46 patients étaient relues, a posteriori, à la recherche de variations anatomiques de la région interscalénique. Les 46 patients, opérés de l’épaule, ont eu un BIS analgésique en une injection. Durant les 30 premières minutes, les blocs sensitifs et moteurs étaient comparés en présence ou non d’une variation.

Résultats

Quarante-neuf pour cent (71/146) des régions présentaient une variation visible en échographie. Trente-trois pour cent (48/146) présentaient un passage intramusculaire d’une racine, 8 % (12/146) possédaient une racine C5 antérieure au muscle scalène antérieur et 23 % (33/146) une artère passant entre les racines ou troncs. Trente-sept pour cent (54/146) présentaient un vaisseau au contact du plexus pouvant gêner l’approche de l’aiguille. Sur les 46 BIS réalisés, la présence d’une variation n’a pas entraîné de différence significative sur les blocs sensitifs et moteurs à la trentième minute (p>0,05).

Conclusion

L’échographie a permis de mettre en évidence de nombreuses variations anatomiques de la région interscalénique. Ces variations ne semblaient pas avoir d’influence sur l’extension anesthésique du BIS en une injection.

El texto completo de este artículo está disponible en PDF.

Abstract

Objectives

This study aimed to evaluate visibility of interscalenic brachial plexus (IBP) variations with ultrasonography (US). Secondary end-point compared success rate of the interscalene block (IB) in shoulder surgery with or without the presence of variation.

Study design

Retrospective descriptive study, conducted in two University Departments of Anesthesiology.

Patients and methods

One hundred and forty-six (27 volunteers and 46 patients) high-resolution US of interscalene region were reviewed. Single shot IB in 46 patients were analyzed over the first 30minutes comparing groups with variation or not.

Results

Forty-nine percent (71/146) regions presented at least one visible variation by US. Thirty-three percent (48/146) showed an intramuscular passage of a root, 8% (12/146) showed a C5 root ahead of the anterior scalene muscle and 23% (33/146) an artery crossing the roots or trunks. Thirty-seven percent (54/146) presented an artery close to the plexus which could be close to the needle. In the forty-six IB performed, the presence of a variation did not show any difference in the sensitive and motor blocks at the 30th minute (p>0.05).

Conclusion

The high-resolution cervical US highlights the IBP variations. These variations appear not to have any relevant influence on the performance of the single shot IB.

El texto completo de este artículo está disponible en PDF.

Mots clés : Plexus brachial, Variations anatomiques, Bloc interscalénique, Échographie

Keywords : Brachial plexus, Variations, Interscalene block, Ultrasound-guidance


Esquema


© 2010  Publicado por Elsevier Masson SAS.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 29 - N° 11

P. 770-775 - novembre 2010 Regresar al número
Artículo precedente Artículo precedente
  • Does an educational strategy based on systematic preoperative assessment of simplified Apfel’s score decrease postoperative nausea and vomiting?
  • S. Sigaut, P. Merckx, C. Peuch, S. Necib, F. Pingeon, J. Mantz
| Artículo siguiente Artículo siguiente
  • Anxiété : facteur prédictif d’échec du bloc axillaire sous neurostimulation ?
  • R. Fuzier, M. Lavidale, B. Bataille, A.-S. Richez, J.-P. Maguès

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
La compra de artículos no está disponible en este momento.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.