Suscribirse

Radiographic preoperative templating of extra-offset cemented THA implants: How reliable is it and how does it affect survival? - 25/10/10

Doi : 10.1016/j.otsr.2010.05.004 
F. Bachour a, E. Marchetti b, c, D. Bocquet b, c, L. Vasseur b, c, H. Migaud b, c, J. Girard b, c,
a Dr Rizk Clinic, BP 113288, Beirut, Lebanon 
b North France Lille University, 59000 Lille, France 
c Orthopedics Dept C, Lille University Hospital, Roger-Salengro Hospital, place de Verdun, 59037 Lille cedex, France 

Corresponding author. Tel.: +33 3 20 44 68 28; fax: +33 3 20 44 66 07.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Summary

Introduction

Securing femoral offset should in theory improve hip stability and abductor muscles moment arms. As problems arise mainly in case of originally increased offset (>40mm), a range of extra-offset stems is available; the exact impact in terms of fixation, however, is not known.

Hypothesis

Extra-offset stems should more reliably reestablish original femoral offsets exceeding 40mm than standard femoral components, limiting instability risk without possible adverse effect on fixation.

Objective

To compare the ability of five commonly available femoral stem designs to restitute offset exceeding 40mm, and to assess function and cement fixation at a minimum 6 years’ follow-up in a stem conceived to reproduce such offset.

Patients and methods

A continuous series of 74 total hip replacements (THR) in hips with increased (>40mm) femoral offset was studied. All underwent preoperative X-ray templating on Imagika™ software to assess offset reproduction by five models of stem: four standard, and one Lubinus SP2™ extra-offset stem. A retrospective clinical and X-ray study was conducted with a minimum 6 years’ follow-up on the Lubinus SP2™ 117° stems used to try to reproduce offset in the 74 THRs.

Results

Apart from the increased (>40mm) offset, the cervicodiaphyseal angle was consistently <135°, <130° in 60 femurs (81%) and <125° in 45 (60%). Planning showed the four standard stems to induce (>5mm femoral offset reduction in 50–83% of cases, versus only 25% with the Lubinus SP2™ 117°). All 74 hips received Lubinus SP2™ 117° stems: at a mean 78 months FU (range, 70–94mo), their mean Postel-Merle d’Aubigné score was 17±1.8 (range, 13–18). Five of the 74 THRs underwent surgical revision: three cases of loosening, in which the stem was replaced, and two of instability, without change of stem. Loosening was not related to offset reproduction quality; two of the three cases were due to initial cementing defect, and the third occurred in a femur with previous history of two osteotomies. There were four cases of dislocation (5.4%: two primary, which were not operated on, and two recurrent, managed by acetabular revision), despite good reproduction of the preoperative offset in three of the four cases. Mean 7-year implant survivorship was 95.1% (±4.8).

Discussion and conclusion

The anatomic form of the Lubinus™ SP2 117° should in theory provide a uniform cement mantle. Survivorship, however, is less good than for regular offset versions (126° or 135°). On the other hand, it does reproduce anatomy in case of >40mm offset, providing extra offset of more than 51mm. The slightly shorter survivorship requires more long-term surveillance.

Level of evidence

Level IV, retrospective study.

El texto completo de este artículo está disponible en PDF.

Keywords : Cemented stem, Offset, Abductor muscle lever arm, Hip abductor moment arm, Survival


Esquema


© 2010  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 96 - N° 7

P. 760-768 - novembre 2010 Regresar al número
Artículo precedente Artículo precedente
  • Shelf arthroplasties long-term outcome: Influence of labral tears. A prospective study at a minimal 16 years’ follows up
  • C. Berton, D. Bocquet, N. Krantz, A. Cotten, H. Migaud, J. Girard
| Artículo siguiente Artículo siguiente
  • Survival analysis of an asymmetric primary total knee replacement: A European multicenter prospective study
  • C. Delaunay, G. Blatter, J.-P. Canciani, D.L. Jones, P. Laffargue, H.W. Neumann, G. Pap, C. Perka, M.J. Sutcliff, H. Zippel, the European “Natural Knee Group (TM)”

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.