Suscribirse

Computer-assisted total knee arthroplasty: Does the tibial component remain at malposition risk? - 25/08/10

Doi : 10.1016/j.otsr.2009.11.017 
J.-C. Bové
Val-de-Sambre Multispecialties Private Hospital, 162, route de Mons, 59600 Maubeuge, France 

Tel.: +00 33 03 27 69 81 96.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Summary

Objectives

The development of computer-assisted surgery in total knee arthroplasty continues its search for better accuracy in the spatial positioning of prosthetic components and in achieving the best ideal ligament balance. Many studies have underscored the value of computer-assisted navigation in obtaining precise bone cuts in terms of both orientation and location, which would optimize bone resection and thereby fulfill ligament balancing requirements. Yet improving bone cut accuracy can be undermined by positioning errors of the component at the final stage of implantation. The objective of this prospective study was to assess this possible loss of accuracy and to suggest possible solutions to minimize this risk.

Material and methods

A consecutive series of 50 total knee arthroplasties was studied using an imageless computer navigation system. This study compared the spatial orientation of the prosthesis components determined using software (frontal positioning for the femoral component, frontal and sagittal positioning for the tibial component) with the recorded orientation of the corresponding bone cuts, which allowed us to quantify the loss of accuracy of these predefined positions after cutting. Trial and final implant orientation was taken into account. Moreover, the mechanical axes of the lower limb, the trial and then the final prosthesis in place were compared. Two procedures were abandoned in the study and two patient files were incomplete, which left a series of 46 cases (29 females and 17 males; mean age at surgery, 67 years; mean BMI, 31.27).

Results

Bone cut orientation was consistently found to be satisfactory. Frontal orientation of the final femoral component (0.2° valgus) did not differ statistically significantly from the distal femoral cut (0.3° valgus) and from the orientation of the trial femoral component, as was true of the slope of the tibial component (4.8°) versus the tibial cut (6.3°) and the mechanical axis of the lower limb with the trial prosthesis and the final implant. The frontal plane orientation of the tibial component (0.6° varus) differed statistically significantly from the bone cut (0.1° valgus).

Discussion

Several studies have demonstrated the value of computer-assisted surgery, notably in the accuracy of the bone cuts, confirming the work reported herein. The loss of accuracy observed between the bone cut and the final implantation can only be explained by soft tissues between the prosthesis and the bone cut, unequal cement thickness, an orientation error in the impaction handle when placing the final implant, or a conflict between the prosthetic keel and cortical bone. Better exposure of the tibial plateaus, discontinuation of cement use, and navigated impaction ancillary tools could reduce these errors.

Level of evidence

Level IV. Prospective study.

El texto completo de este artículo está disponible en PDF.

Keywords : Computer-assisted surgery, Total knee arthroplasty


Esquema


© 2010  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 96 - N° 5

P. 536-542 - septembre 2010 Regresar al número
Artículo precedente Artículo precedente
  • Can Blount’s disease heal spontaneously?
  • J.-M. Laville, Y. Wiart, F. Salmeron
| Artículo siguiente Artículo siguiente
  • Patella osteochondritis dissecans end stage: The osteochondral mosaicplasty option
  • E. Visonà, J. Chouteau, R. Aldegheri, M.H. Fessy, B. Moyen

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.