Summary

Background

Type C periprosthetic femoral fractures present fixation problems related to the extent of the fracture and the quality of the bone stock.

Objectives

The authors report a continuous and prospective series of type C periprosthetic femoral fractures to assess the mechanical stability of the femoral implant and the clinical outcome at the medium term.

Material and methods

Between April 2004 and November 2006, we treated 17 patients (15 females, two males) presenting a prosthetic hip fracture (12 cases), between the hip prosthesis and the knee (one case), and with a knee prosthesis (four cases). All the implants had no sign of loosening at the time of fracture. The patients’ mean age was 76.7 years (range, 39–93 years). Internal fixation was obtained with a locking compression plate (LCP) Synthes™ bridging the implant in place to prevent a weak zone. The rehabilitation protocol consisted in full weightbearing as much as possible.

Results

The mean follow-up of the series was 31.5 months (range, 4–51 months). Four deaths were recorded during the follow-up. Minimally invasive surgery was performed in 15 patients. Total loading was possible immediately in 10 patients, partial loading at 20 kg in three patients, and no loading was possible until 6 weeks in four patients. Two infections and a bending-type mechanical complication of the plate secondary to a fall were observed. Consolidation was obtained in all cases with the appearance of callus formation beginning in the 6th week.

Discussion

The technique used allies the principle of closed internal fixation (with preservation of the fracture hematoma) with mechanical stability. The screws locking to the plate warrant an internal fixator with increased stability that is sufficient for early loading with no risk of losing the secondary axis. Despite this increased rigidity, we did not observe any particular stress on the femoral implants. We recommend bridging the implant and spaced locking for better distribution of the stresses during loading. This hardware, with, if possible, insertion using a reduced approach, seems adapted to periprosthetic femoral fractures, particularly in the elderly.

Level of evidence

Level IV, prospective therapeutic study.

El texto completo de este artículo está disponible en PDF.

Keywords : Femoral fracture, Locking plate, Periprosthetic fracture, Minimally invasive surgery


Esquema


© 2009  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 96 - N° 1

P. 44-48 - février 2010 Regresar al número
Artículo precedente Artículo precedente
  • Patellar height relevance in opening-wedge high tibial osteotomy
  • M.H. El Amrani, B. Lévy, S. Scharycki, A. Asselineau
| Artículo siguiente Artículo siguiente
  • Infection risk prevention following total knee arthroplasty
  • T. Levent, D. Vandevelde, J.-M. Delobelle, P. Labourdette, J. Létendard, P. Lesage, P. Lecocq, M. Dufour

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.