Suscribirse

Femoral deficiency reconstruction using a hydroxyapatite-coated locked modular stem. A series of 43 total hip revisions - 25/04/09

Doi : 10.1016/j.otsr.2008.09.009 
R. Philippot a, b, , F. Delangle a, F.-X. Verdot a, F. Farizon a, M.-H. Fessy a
a EA 4338, laboratoire de physiologie de l’exercice, Saint-Étienne, France 
b Department of Orthopaedics and Traumatology, Pavillon 1–3, Bellevue Hospital, 25, boulevard Pasteur, 42055 Saint-Étienne cedex 2, France 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Summary

Introduction

We report a continuous prospective series of patients operated on for total hip prosthesis femoral component loosening involving a bone defect. Reconstruction was performed using a hydroxyapatite-coated locked modular stem. The study’s objective was to assess medium term clinical and X-ray results obtained with this original concept.

Materials and methods

The patients included received a REEF® (DePuy) femoral implant for aseptic loosening or loosening associated with a periprosthetic fracture. Implantation was systematically accompanied by an extended trochanteric osteotomy (ETO). Patients were followed up prospectively by clinical and X-ray examination. Their loosening was graded at inclusion according to Vives’ classification as revised by SOFCOT in 1999. Analysis focused on actuarial implant survivorship, dislocation and the bone/implant interface.

Results

Forty-three hips were included: mean follow-up was 58.2 months (12–92) and mean age at surgery was 72.4 years (37–94). The main indications were severe bone loss rated grade III (n=15) or IV (n=16) according to the SOFCOT classification. There was one long-term failure, involving implant fracture secondary to nonunion of the femoral shaft. Mean Postel and Merle d’Aubigné (PMA) clinical assessment score increased from six preoperatively to 14.5 at end of follow-up. X-ray analysis found no stem migration by end of follow-up. There was consistent consolidation of the ETO around the stem, except in one case of stem fracture which evolved into tight nonunion. In terms of metaphyseal integration, five patients showed radiolucency without evolution over follow-up, and eight had severe calcar cortical atrophy at end of follow-up. Mean 5-year actuarial survivorship was 97.7±2.3%, with a 2% incidence of dislocation.

Discussion

The complications rate was low, and results were comparable with those reported in the literature. The study confirmed the interest of the extended trochanteric osteotomy exposure and the effectiveness of the hydroxyapatite-coated interlocked modular stem concept in the treatment of hip prosthesis loosening with femoral bone loss (involving or not the cortex). On analysis, the one case of failure does not proscribe the surgical technique employed. Implant osseointegration was difficult to analyze. The extent of the surgical approach and of its corresponding sequels, combined with the complexity of adjusting the implant, however, restrict this surgical option indications to level III and IV cases of femoral loosening.

Level of evidence: level IV; therapeutic study.

El texto completo de este artículo está disponible en PDF.

Keywords : Revision total hip replacement, Interlocking fixation, Modular stem


Esquema


© 2009  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 95 - N° 2

P. 119-126 - avril 2009 Regresar al número
Artículo precedente Artículo precedente
  • Frohse’s arcade is not the exclusive compression site of the radial nerve in its tunnel
  • P. Clavert, J.C. Lutz, P. Adam, R. Wolfram-Gabel, P. Liverneaux, J.L. Kahn
| Artículo siguiente Artículo siguiente
  • Is early weight bearing resumption beneficial after total hip replacement?
  • J. Merle, P. Rougier, D. Belaid, S. Cantalloube, D. Lamotte

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

@@150455@@ Voir plus

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2026 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.