Suscribirse

NCB-PP® locking plates outcomes in the treatment of periprosthetic femoral fractures. Analysis of a retrospective cohort of 89 patients - 01/10/24

Doi : 10.1016/j.otsr.2024.104009 
Batiste Santoni a, b, , Marie Le Baron a, Pascal Maman a, Richard Volpi a, Xavier Flecher a
a Service de Chirurgie Orthopédique et Traumatologique, Centre Hospitalo-Universitaire Nord, Hôpital Nord, chemin des Bourrely, 13015 Marseille, France 
b Service de Chirurgie Orthopédique et Traumatologique, CHU de Pointe-à-Pitre-Abymes, route de Chauvel, 97142 Les Abymes, France 

Corresponding author at: Service de chirurgie orthopédique et traumatologique, Centre Hospitalo-Universitaire Nord, Hôpital Nord, chemin des Bourrely, 13015 Marseille, France.Service de chirurgie orthopédique et traumatologiqueCentre Hospitalo-Universitaire Nord, Hôpital Nordchemin des BourrelyMarseille13015France
En prensa. Pruebas corregidas por el autor. Disponible en línea desde el Tuesday 01 October 2024

Abstract

Introduction

The management of periprosthetic femoral fractures is particularly complex in an elderly, frail population, with an increasing incidence due to the increase in femoral prosthesis surgery. The use of locking plates is now widely recommended. The primary objective of this study was to present the results of NCB-PP® locking plates in the management of periprosthetic femoral fractures. The secondary objective was to determine the influence of weight-bearing time on morbidity and mortality and on walking ability. The hypothesis of this study was that NCB-PP® plates would provide radio-clinical results equivalent to those reported in the literature with no influence of time to re-weighting on complication rate and walking level at 1 year post-operatively.

Materials and methods

89 patients (mean age 81 ± 11.9 (28−99), with a female predominance 62/89 (69.7%)) underwent 89 periprosthetic femur fractures (74 THA, 11 TKA and 4 interprosthetic) and treated with NCB-PP® plates were retrospectively included between January 2014 and September 2022. Patients were then divided into 2 groups according to the time to postoperative full weight bearing: "immediate" (n = 30) and "delayed" (n = 59) (a minimum of 6 weeks post-operatively).

Results

The mean follow-up time was 14.6 months. At 6 months post-operatively, 91.8% of patients were consolidated. At 1 year, 36.2% had resumed independent walking, 8.7% required one crutch, 13% two crutches, 33.3% walked with a walker and 8.7% were considered non-walkers. There were 12 complications (13.5%), including 7 mechanical (7.9%) and 5 infections (5.6%), with 10 patients (11.2%) requiring a revision surgery. Mortality at 6 months and 1 year was respectively 9 and 12.4%. There was no significant difference between pre- and post-operative walking levels (p = 0.45). There was no influence of the time to reweighting on the level of walking at 1 year (p = 0.874), on complications (p = 0.17) or on mortality at 1 year (p > 0.99).

Conclusion

This study confirms the initial hypothesis and the results of preliminary studies on a smaller sample size regarding bone union of periprosthetic femoral fractures with NCB-PP® plates, with a low rate of mechanical complications. The proportion of patients returning to their previous walking level remains low, but early full weight bearing is still possible without increasing the rate of mechanical complications.

Level of evidence

IV; retrospective cohort study.

El texto completo de este artículo está disponible en PDF.

Keywords : Periprosthetic femoral fracture, Locking plates, Bone union, Complications


Esquema


© 2024  Elsevier Masson SAS. Reservados todos los derechos.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.