Suscribirse

Psychometric evaluation of the modified quality of recovery score for the postanaesthesia care unit (QoR-PACU2)—A prospective validation study - 17/05/24

Doi : 10.1016/j.accpm.2024.101380 
Ursula Kahl a, Alena Boehm a, Linda Krause b, Regine Klinger a, Kaloyan Stoimenov a, Christian Zöllner a, Lili Plümer a, 1, Marlene Fischer a, c, , 1
a Department of Anaesthesiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany 
b Institute of Medical Biometry and Epidemiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany 
c Department of Intensive Care Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany 

Corresponding author.

Abstract

Background

To date, there is no instrument to adequately assess self-reported quality of recovery (QoR) in the post-anesthesia care unit (PACU). We previously developed the QoR-PACU, a 13-item questionnaire specifically applicable to the PACU. The feasibility, acceptance, and validity of the QoR-PACU were promising. However, measures of reliability were slightly lower than expected.

Methods

We modified the QoR-PACU and evaluated its psychometric properties in a cohort of adult patients scheduled for non-cardiac surgery with general anesthesia. The modified QoR-PACU (termed QoR-PACU2) was administered before surgery and postoperatively in the PACU at the time of the decision to discharge.

Results

A total of 307 patients were included in the final analysis. Postoperative QoR-PACU2 sum scores differed across categories of sex, perioperative and surgical risk, and modes of airway management. The duration of anesthesia and surgery, maximum pain intensity and analgesic requirement in the PACU, and length of PACU stay were all inversely correlated with QoR in the PACU. Cronbach’s alpha was 0.70 (95%CI: 0.66–0.75). The intra-class correlation coefficient was 0.86 (95%CI: 0.70–0.94, p < 0.001) for intra-rater reliability (n = 24) and 0.94 (95%CI 0.90 to 0.97, p < 0.001) for inter-rater reliability (n = 31). Cohen’s effect size was 0.68 and the standardized response mean was 0.57.

Conclusion

The QoR-PACU2 assesses self-reported QoR after surgery in the PACU. Measures of feasibility, validity, and reliability were consistently high. Measures of responsiveness were moderate, which might be attributable to the heterogeneity of the study population. Future studies should include aspects of ethnicity and cross-cultural applicability.

El texto completo de este artículo está disponible en PDF.

Keywords : Quality of recovery, Post-anesthesia care unit, Early postoperative recovery, Patient-reported outcome, Perioperative care, Questionnaire


Esquema


© 2024  The Author(s). Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 43 - N° 3

Artículo 101380- juin 2024 Regresar al número
Artículo precedente Artículo precedente
  • Comparison of the bispectral indices of patients receiving remimazolam and propofol for general anesthesia: a randomized crossover trial
  • Chen Yang, Jing Jiao, Yuyan Nie, Wenyu Shao, Hongwei Zhang, Shaoqiang Huang
| Artículo siguiente Artículo siguiente
  • Dexmedetomidine and acute kidney injury after non-cardiac surgery: A meta-analysis with trial sequential analysis
  • Kai Zhuang, Hao-tian Yang, Yu-qin Long, Hong Liu, Fu-hai Ji, Ke Peng

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
El acceso al texto completo de este artículo requiere una suscripción.

¿Ya suscrito a @@106933@@ revista ?

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2024 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.