Suscribirse

Kneeling tolerance following intramedullary nailing or plate fixation of uncomplicated distal tibia fractures - 19/08/23

Doi : 10.1016/j.otsr.2022.103497 
Benjamin A. Southi a, , 1 , Callum Fryer a, Jay Ebert c, Tim Ackland c, Markus S. Kuster a, b, Nicholas D. Calvert a
a Department of Orthopaedics, Royal Perth Hospital, Perth, WA, Australia 
b Department of Orthopaedics, Sir Charles Gairdner Hospital, Perth, WA, Australia 
c School of Human Sciences (Exercise and Sport Science), University of Western Australia, Perth, Australia 

Corresponding author.

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.
Artículo gratuito.

Conéctese para beneficiarse!

Abstract

Introduction

Distal tibia fractures often occur in younger, high demand patients, though the literature surrounding management remains contentious. This study sought to quantitatively determine differences in kneeling ability and self-reported knee function in patients managed with either intramedullary nailing (IMN) or open reduction internal fixation (ORIF) with compression plating following distal tibia fracture to assist in the preoperative consent process.

Hypothesis

There is no difference in kneeling tolerance following either tibial nailing or plate fixation of distal tibia fractures.

Material and methods

Retrospective sampling of public hospital data with outpatient prospective functional testing were completed. The primary outcome measure was the Kneeling Test (KT). Secondary outcome measures were The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and the Forgotten Joint Score (FJS) for the knee joint. There were 28 patients recruited (18 IMN and 10 ORIF) with a mean age of 44years. Mean overall follow-up was 13.3months (range 8–25, SD 3.6). All fractures had completely healed without postoperative complication.

Results

The IMN affected limb had a significantly worse overall kneeling function than their non-affected limb (mean KT: 70.4 vs. 94.9 respectively, p<0.005) Additionally, the IMN group performed significantly worse when compared to the ORIF group (mean KT 70.4 vs. 92.5 respectively, p<0.005). No significant differences (p>0.05) in kneeling function existed for the ORIF group when comparing affected to non-affected limbs. Secondary outcome analysis showed significantly worse overall WOMAC and FJS in the IMN group compared to the ORIF group (mean WOMAC 19.3 vs. 6.9 respectively, p=0.040; mean FJS 38.3 vs. 75.9 respectively, p=0.005).

Discussion

The use of intramedullary nailing for the treatment of distal tibia fracture results in a mean reduction of 20% in kneeling tolerance in comparison to ORIF. The resulting kneeling tolerance is comparable to that of patients post-total knee arthroplasty. The present findings should assist in the consent process for patients with high kneeling demands in sportive, professional or cultural pastimes.

Level of evidence

IV; retrospective cohort study with quantitative outcome measurement.

El texto completo de este artículo está disponible en PDF.

Keywords : Kneeling tolerance, Distal tibia fracture, Trauma orthopaedics, Intramedullary nail, Compression plating


Esquema


Crown Copyright © 2022  Publicado por Elsevier Masson SAS. Todos los derechos reservados.
Añadir a mi biblioteca Eliminar de mi biblioteca Imprimir
Exportación

    Exportación citas

  • Fichero

  • Contenido

Vol 109 - N° 5

Artículo 103497- septembre 2023 Regresar al número
Artículo precedente Artículo precedente
  • Gait recovery is not associated with meniscus and/or knee ligament injuries following lateral tibial plateau fractures. A prospective 3-year cohort study of 56 patients
  • Peter Larsen, Rasmus Elsoe
| Artículo siguiente Artículo siguiente
  • Tension band wiring versus screw fixation for the treatment of medial malleolar fractures: A systematic review and meta-analysis
  • Chul-Ho Kim, Dae Sung Ma, Yong-Cheol Yoon

Bienvenido a EM-consulte, la referencia de los profesionales de la salud.

Mi cuenta


Declaración CNIL

EM-CONSULTE.COM se declara a la CNIL, la declaración N º 1286925.

En virtud de la Ley N º 78-17 del 6 de enero de 1978, relativa a las computadoras, archivos y libertades, usted tiene el derecho de oposición (art.26 de la ley), el acceso (art.34 a 38 Ley), y correcta (artículo 36 de la ley) los datos que le conciernen. Por lo tanto, usted puede pedir que se corrija, complementado, clarificado, actualizado o suprimido información sobre usted que son inexactos, incompletos, engañosos, obsoletos o cuya recogida o de conservación o uso está prohibido.
La información personal sobre los visitantes de nuestro sitio, incluyendo su identidad, son confidenciales.
El jefe del sitio en el honor se compromete a respetar la confidencialidad de los requisitos legales aplicables en Francia y no de revelar dicha información a terceros.


Todo el contenido en este sitio: Copyright © 2025 Elsevier, sus licenciantes y colaboradores. Se reservan todos los derechos, incluidos los de minería de texto y datos, entrenamiento de IA y tecnologías similares. Para todo el contenido de acceso abierto, se aplican los términos de licencia de Creative Commons.